A Specifications Compaq Evo Small Form Factor Desktop Dimensions Height Width Depth 3.8 in 13.1 in 14.6 in 9.7 cm 33.3 cm 37.1 cm Approximate Weight 20.0 lb 9.1 kg Weight Supported (maximum distributed load) 100.0 lb 45.5 kg Temperature Range Operating Nonoperating 50° to 95° F -22° to 140° F 10° to 35° C -30° to 60° C Relative Humidity (noncondensing) Operating Nonoperating 10-90% 5-95% 10-90% 5-95% Maximum Altitude (unpressurized) Operating Nonoperating 10,000 ft 30,000 ft 3048 m 9144 m ✎ Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Power Supply Operating Voltage Range Rated Voltage Range Rated Line Frequency 90-264 VAC 100-240 VAC 50-60 Hz 90-264 VAC 100-240 VAC 50-60 Hz ✎ This system utilizes a full ranging, active power factor corrected power supply to greatly reduce the input current amplitude and harmonics. No input voltage select switch is required. Hardware Reference Guide A-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63

Hardware Reference Guide
A–1
A
Specifications
Compaq Evo Small Form Factor
Desktop Dimensions
Height
Width
Depth
3.8 in
13.1 in
14.6 in
9.7 cm
33.3 cm
37.1 cm
Approximate Weight
20.0 lb
9.1 kg
Weight Supported (maximum distributed load)
100.0 lb
45.5 kg
Temperature Range
Operating
Nonoperating
50
°
to 95
°
F
-22
°
to 140
°
F
10
°
to 35
°
C
-30
°
to 60
°
C
Relative Humidity (noncondensing)
Operating
Nonoperating
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea
level, no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may
be limited by the type and number of options installed.
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
90-264 VAC
100-240 VAC
50-60 Hz
90-264 VAC
100-240 VAC
50-60 Hz
This system utilizes a full ranging, active power factor corrected power supply to greatly
reduce the input current amplitude and harmonics. No input voltage select switch is
required.