Craftsman 29906 Owners Manual - Page 66

lect the oil's SAE viscosity

Page 66 highlights

_L, CAUTION: Disconnect spark plug wire before performing any maintenance (except carburetor adjustment) to prevent accidental starting of engine. Prevent fires! Keep the engine free of grass, leaves, spilled oil, or fuel. Remove fuel from tank before tipping unit for maintenance. Clean muffler area of all grass, dirt, and debris. Do not touch hot muffler or cylinder fins as contact may cause burns. ENGINE LUBRiCATiON 5. Refill engine with oil. See "CHECK ENGINE OIL LEVEE' in the Operation section of this manual. Oil drain Level Oil Fill Plug Use only high quality detergent oil rated with API service classification SG-SL Select the oil's SAE viscosity grade according to your expected temperature. SAE VISCOSITY GRADES =20 0 20 40 60 80 100°F | l l 1 J [ • 1 =30 =20 =10 0 10 20 30 40 ° C TEMPERATURE RANGE ANTiCiPATED BEFORE NEXT OiL CHANGE NOTE: Although multi-viscosity oils (5W-30, 10W-30, etc.) improve starting in cold weather, they will result in increased oil consumption when used above 32°F (0°C). Check your engine oil level more frequently to avoid possible engine damage from running low on oil. Change the oil after every 25 hours of operation or at least once a year if the tiller is not used for 25 hours in one year. Check the crankcase oil level before starting the engine and after each five (5) hours of continuous use. Add SAE 30 mo- tor oil or equivalent. Tighten oil filler plug securely each time you check the oil level. AiR CLEANER Service air cleaner cartridge every twenty-five hours, more often if engine is used in very dusty conditions. 1. Loosen air cleaner screw. 2. Remove air cleaner cover. 3. Carefully remove air cleaner cartridge. Be careful. Do not allow dirt or debris to fall into carburetor. 4. Clean by tapping gently on a flat surface. NOTE: If very dirty or damaged, replace cartridge. 5. Clean and replace cover. Tighten screw securely. _CAUTION: Petroleum solvents, such as kerosene, are not to be used to clean cartridge. They may cause deterioration of the cartridge. Do not oil cartridge. Do not use pressurized air to clean or dry cartridge. Air Cleaner Cartridge Pre-Cleaner Cover TO CHANGE ENGINE OIL Determine temperature range expected before oil change. All oil must meet API service classification SG-SL • Be sure tiller is on level surface. • Oil will drain more freely when warm. • Use a funnel to prevent oil spill on tiller, and catch oil in a suitable container. 1. Remove drain plug. 2. Tip tiller forward to drain oil. 3. After oil has drained completely, replace oil drain plug and tighten securely. 4. Remove oil filler plug. Be careful not to allow dirt to enter the engine. 14 Air Cleaner Screws

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

_L,CAUTION:
Disconnect
spark
plug
wire before
performing
any maintenance
(except
carburetor
adjustment)
to prevent
accidental
starting
of engine.
Prevent
fires!
Keep the engine free of
grass,
leaves,
spilled
oil, or fuel.
Remove
fuel from tank before tipping
unit for main-
tenance.
Clean
muffler
area of all grass,
dirt, and debris.
Do not touch
hot muffler
or cylinder
fins as
contact
may cause
burns.
ENGINE
LUBRiCATiON
Use only high quality
detergent
oil rated
with API service
classification
SG-SL
Se-
lect the oil's SAE viscosity
grade
accord-
ing
to your expected
temperature.
SAE
VISCOSITY
GRADES
=20
0
20
40
60
80
100°F
|
l
l
1
J
[
1
=30
=20
=10
0
10
20
30
40 ° C
TEMPERATURE
RANGE
ANTiCiPATED
BEFORE
NEXT
OiL
CHANGE
NOTE:
Although
multi-viscosity
oils
(5W-30,
10W-30,
etc.)
improve
starting
in
cold weather,
they will result
in
increased
oil consumption
when used
above 32°F
(0°C).
Check
your engine
oil level more
frequently
to avoid possible
engine
dam-
age from running
low on oil.
Change
the oil after every 25 hours of op-
eration
or at least once a year
if
the tiller
is
not used for 25 hours
in
one year.
Check
the crankcase
oil level before
starting
the engine
and after each five (5)
hours of continuous
use.
Add SAE 30 mo-
tor oil or equivalent.
Tighten
oil filler
plug
securely
each time you check the oil level.
TO
CHANGE
ENGINE
OIL
Determine
temperature
range
expected
before
oil change.
All oil must
meet API
service
classification
SG-SL
Be sure tiller
is on level surface.
Oil will drain
more freely
when warm.
Use a funnel to prevent
oil spill on tiller,
and catch oil
in
a suitable
container.
1.
Remove
drain plug.
2.
Tip tiller forward
to drain oil.
3.
After oil has drained
completely,
replace
oil drain
plug and tighten
se-
curely.
4.
Remove
oil filler plug.
Be careful
not
to allow
dirt to enter the engine.
5.
Refill
engine
with
oil.
See
"CHECK
ENGINE
OIL
LEVEE'
in the
Operation
section
of this
manual.
Oil drain
Level
Oil Fill Plug
AiR
CLEANER
Service
air cleaner
cartridge
every
twenty-five
hours,
more
often
if
engine
is
used
in very
dusty
conditions.
1.
Loosen
air cleaner
screw.
2.
Remove
air cleaner
cover.
3.
Carefully
remove
air cleaner
cartridge.
Be careful.
Do not
allow
dirt
or debris
to fall
into carburetor.
4.
Clean
by tapping
gently
on
a flat
sur-
face.
NOTE:
If very
dirty
or damaged,
replace
cartridge.
5.
Clean
and
replace
cover.
Tighten
screw
securely.
_CAUTION:
Petroleum
solvents,
such
as
kerosene,
are
not to be
used
to
clean
cartridge.
They
may
cause
deterioration
of the
cartridge.
Do
not oil cartridge.
Do
not
use pressurized
air to
clean
or dry
cartridge.
Air Cleaner
Cartridge
Pre-Cleaner
Cover
Air Cleaner
Screws
14