Planning the Installation Cabinet Layout • Carefully check the location where the range is to be installed. For best performance, the range should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets. • To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a range hood. A range hood should project horizontally a minimum of five (5) inches beyond the face of the cabinets. • All maximum and minimum dimensions and clearances shown in the diagram below and on page 8 (as applicable) must be maintained for safe operation. • In the freestanding configuration, the range may be installed flush to the rear wall. For all installations, Dacor highly recommends installing a non-combustible material on the rear wall above the range and up to the vent hood or installation of a backguard. It is not necessary to install non-combustible materials behind the range below the countertop height. • Any openings in the wall behind the appliance or in the floor underneath it must be sealed. Gas and Electrical Service • The shaded area shown denotes the location of the gas inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve locations. • An external manual shut-off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance. The installation must allow for the following: • Access to the gas shut-off valve when the unit is installed. • Access to the remote circuit breaker panel or fuse box, when the range is in place. • The gas supply piping, gas shut-off valve and the electrical junction box or receptacle must be located so they do not interfere with the range when it is installed. • The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected. Cutout tolerances: +1/16" (+1.6 mm), -0 F WARNING Do not operate the range without the backguard in place if the back wall is made of combustible materials. A fire may result. 13" (330 mm) Max.4 18" (457 mm) Min.1, 4 Non-combustible surface along back wall recommended 30" (762 mm) Min.1 G FREESTANDING CUTOUT DIMENSIONS F G 36" (914 mm)* 30" (762 mm)** 30 1/16" (764 mm)* * Recommended ** Minimum See following page for self-rimming cutout dimensions. 10" (254 mm) Min. to combustible side walls above the range (both sides) Note 2 36 1/2" (927 mm) Max. Suggested location of utilities 3 1 Vertical to combustible surface from range grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 Cabinet/countertop depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimensions. 3 Consult local code for exact location requirements. 4 Not applicable for cabinets more than a horizontal distance of 10" (254 mm) from the edge of the range. Freestanding Cabinet Cutout Dimensions Models ER30D and ER30D-C 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

7
Planning the Installation
Cabinet Layout
Carefully check the location where the range is to be
installed. For best performance, the range should be placed
away from drafts that may be caused by doors, windows and
heating and air conditioning outlets.
To reduce the risk of personal injury and to reduce
accumulated smoke in the room, Dacor strongly recommends
installing a range hood. A range hood should project
horizontally a minimum of five (5) inches beyond the face of
the cabinets.
All maximum and minimum dimensions and clearances
shown in the diagram below and on page 8 (as applicable)
must be maintained for safe operation.
In the freestanding configuration, the range may be installed
flush to the rear wall. For all installations, Dacor highly
recommends installing a non-combustible material on the rear
wall above the range and up to the vent hood or installation
of a backguard. It is not necessary to install non-combustible
materials behind the range below the countertop height.
Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
Gas and Electrical Service
The shaded area shown denotes the location of the gas
inlet and the electrical junction box/receptacle. This is the
recommended location. For replacement purposes, the
location of the existing utilities may be utilized provided they
do not interfere with the sides or rear of the range. Check
local building codes for permissible gas valve locations.
An external manual shut-off valve must be installed between
the gas inlet and the range for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the remote circuit breaker panel or fuse box, when
the range is in place.
The gas supply piping, gas shut-off valve and the electrical
junction box or receptacle must be located so they do not
interfere with the range when it is installed.
The junction box and gas shut off valve must be located
so that the range can be pulled out for service while the
appliance remains connected.
Freestanding Cabinet Cutout Dimensions -
Models ER30D and ER30D-C
Note 2
F
G
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
1
Vertical to combustible surface from range grate level; if
installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
Non-combustible
surface along
back wall
recommended
10” (254 mm) Min.
to combustible side
walls above the range
(both sides)
30” (762 mm)
Min.
1
36 1/2”
(927 mm)
Max.
13” (330 mm)
Max.
4
18” (457 mm)
Min.
1, 4
Suggested
location of
utilities
3
4
Not applicable for cabinets more than a horizontal
distance of 10” (254 mm) from the edge of the range.
Cutout tolerances: +1/16” (+1.6 mm), -0
FREESTANDING CUTOUT
DIMENSIONS
F
G
36” (914 mm)*
30” (762 mm)**
30 1/16” (764 mm)*
* Recommended
** Minimum
See following page for self-rimming cutout
dimensions.
WARNING
Do not operate the range without the backguard in place if the
back wall is made of combustible materials. A fire may result.