Dell Brocade 6505 Brocade 6505 Hardware Reference Manual - Page 41

Determining the need to replace a power supply and fan assembly, In Web Tools, click

Page 41 highlights

Removing and replacing a power supply and fan assembly 4 TABLE 4 LED color Power supply and fan assembly status LED behavior, description, and required actions Description Action required No light Steady green Flashing green (for more than 5 seconds) Power supply and fan assembly is not receiving power, or is off. Verify that the power supply and fan assembly is on and seated and the power cord is connected to a functioning power source. Power supply and fan assembly is operating normally. No action is required. Power supply and fan assembly is faulty for one of the following reasons: • The assembly is switched off - flashing for ~ 5 seconds, then off • The power cable is disconnected - flashing for ~ 5 seconds, then off • The power supply and fan assembly has failed NOTE: When the Brocade 6505 is first powered on, the power supply and fan assembly status LED will flash until POST has completed. Try one of the following: • Check the power cable connection. • Verify that the assembly is powered on. • Replace the power supply and fan assembly. Determining the need to replace a power supply and fan assembly Use one of the following methods to determine the status of the power supplies: • Check the power supply and fan assembly status LED next to the on/off switch (refer to "LED locations" on page 18). • In Web Tools, click the Power Status icon. • Enter the psShow command at the prompt to display power supply and fan assembly status in the following example: br6505:admin> psshow Power Supply #1 is OK Power Supply #2 is absent br6505:admin> Alternatively, you can enter the fanShow or chassisShow commands to determine the status of the power supply and fan assembly: br6505:admin> fanshow Fan 1 is OK, speed is 8653 RPM Fan 2 is absent br6505:admin> br6505:admin> chassisshow FAN Unit: 1 Fan Direction: Time Awake: Forward 0 days Brocade 6505 Hardware Reference Manual 29 53-1002449-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Brocade 6505 Hardware Reference Manual
29
53-1002449-01
Removing and replacing a power supply and fan assembly
4
Determining the need to replace a power supply and fan assembly
Use one of the following methods to determine the status of the power supplies:
Check the power supply and fan assembly status LED next to the on/off switch (refer to
“LED locations”
on page 18).
In Web Tools, click the
Power Status
icon.
Enter the
psShow
command at the prompt to display power supply and fan assembly
status in the following example:
br6505:admin>
psshow
Power Supply #1 is OK
Power Supply #2 is absent
br6505:admin>
Alternatively, you can enter the
fanShow
or
chassisShow
commands to determine the
status of the power supply and fan assembly:
br6505:admin>
fanshow
Fan 1 is OK, speed is 8653 RPM
Fan 2 is absent
br6505:admin>
br6505:admin>
chassisshow
FAN
Unit: 1
Fan Direction:
Forward
Time Awake:
0 days
TABLE 4
Power supply and fan assembly status LED behavior, description, and required
actions
LED color
Description
Action required
No light
Power supply and fan assembly is not receiving
power, or is off.
Verify that the power supply and fan
assembly is on and seated and the
power cord is connected to a
functioning power source.
Steady green
Power supply and fan assembly is operating
normally.
No action is required.
Flashing green (for
more than 5 seconds)
Power supply and fan assembly is faulty for one
of the following reasons:
The assembly is switched off - flashing for
~ 5 seconds, then off
The power cable is disconnected - flashing
for ~ 5 seconds, then off
The power supply and fan assembly has
failed
NOTE: When the Brocade 6505 is first powered
on, the power supply and fan assembly status
LED will flash until POST has completed.
Try one of the following:
Check the power cable
connection.
Verify that the assembly is
powered on.
Replace the power supply and fan
assembly.