Dell Brocade 6505 Brocade 6505 Hardware Reference Manual - Page 49

Access Gateway default port mapping, Regulatory compliance

Page 49 highlights

Access Gateway default port mapping A The serial port can be used to connect to a workstation to configure the switch IP address before connecting the switch to a fabric or IP network. The serial port's parameters are fixed at 9600 baud, 8 data bits, and no parity, with flow control set to None. Table 12 lists the serial cable pinouts. TABLE 12 Serial cable pinouts PIN Signal Description 1 Not supported 2 Not supported 3 UART1_TXD 4 GND 5 GND 6 UART1_RXD 7 Not supported 8 Not supported N/A N/A Transmit data Logic ground Logic ground Receive data N/A N/A Access Gateway default port mapping Table 13 lists the port mappings of F_Ports to N_Ports. TABLE 13 Access Gateway default port mapping Total ports F_Ports N_Ports Default port mapping 24 0-15 16-23 0,1 mapped to 16 2,3 mapped to 17 4,5 mapped to 18 6,7 mapped to 19 8,9 mapped to 20 10,11 mapped to 21 12,13 mapped to 22 14,15 mapped to 23 Regulatory compliance This section describes the following regulatory compliance requirements for the Brocade 6505: It contains: • "FCC warning (US only)" on page 38 • "German statement" on page 38 • "KCC statement (Republic of Korea)" on page 38 • "VCCI statement (Japan)" on page 38 • "Power cords (Japan DENAN)" on page 39 • "Chinese statement" on page 39 • "BSMI statement (Taiwan)" on page 39 • "CE statement" on page 39 Brocade 6505 Hardware Reference Manual 37 53-1002449-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Brocade 6505 Hardware Reference Manual
37
53-1002449-01
Access Gateway default port mapping
A
The serial port can be used to connect to a workstation to configure the switch IP address before
connecting the switch to a fabric or IP network. The serial port’s parameters are fixed at 9600
baud, 8 data bits, and no parity, with flow control set to None.
Table 12
lists the serial cable pinouts.
Access Gateway default port mapping
Table 13
lists the port mappings of F_Ports to N_Ports.
Regulatory compliance
This section describes the following regulatory compliance requirements for the Brocade 6505: It
contains:
“FCC warning (US only)”
on page 38
“German statement”
on page 38
“KCC statement (Republic of Korea)”
on page 38
“VCCI statement (Japan)”
on page 38
“Power cords (Japan DENAN)”
on page 39
“Chinese statement”
on page 39
“BSMI statement (Taiwan)”
on page 39
“CE statement”
on page 39
TABLE 12
Serial cable pinouts
PIN
Signal
Description
1
Not supported
N/A
2
Not supported
N/A
3
UART1_TXD
Transmit data
4
GND
Logic ground
5
GND
Logic ground
6
UART1_RXD
Receive data
7
Not supported
N/A
8
Not supported
N/A
TABLE 13
Access Gateway default port mapping
Total ports
F_Ports
N_Ports
Default port mapping
24
0-15
16-23
0,1 mapped to 16
2,3 mapped to 17
4,5 mapped to 18
6,7 mapped to 19
8,9 mapped to 20
10,11 mapped to 21
12,13 mapped to 22
14,15 mapped to 23