PS6610 Hardware Owner's Manual 3 Control Module Maintenance LED Name State Off Steady red ERR Blinking red PWR Off On (steady green) Description Normal operation or no power Array is starting up, in error condition, in Standby mode, or returning from Standby mode. Array is entering power standby mode because the Standby On/Off button was pressed. No power Power/OK Identify Control Module Failures You can identify a failure in a control module by: • LEDs on the control module itself. See Interpreting Control Module LEDs on page 16. • Messages on the console, in the event log, or in the Group Manager GUI Alarms panel. • Group Manager GUI and CLI output. The Member Controllers window or the member select show controllers command output shows the control module status not installed. When viewed from the rear of the array, CM0 is on the left and CM1 is on the right. If a control module fails, contact your PS Series support provider for a replacement. About Failover Behavior In a dual control module array, only one control module is active (processing network I/O and performing storage functions) at one time. Each control module stores recently used data. For redundancy, the cache on the secondary control module mirrors the data that is stored in the cache on the active control module. The active control module can use the network interfaces of the secondary control module for failover if a cable is connected from the corresponding port on the secondary control module to a functioning network switch. Note: The management ports on the control modules do not fail over if one control module fails. Therefore, if you are using a dedicated management network, make sure the management ports on both control modules are connected to the management network. A PS Series array provides the following types of network failure protection: • Vertical failover. In a dual control module array, a network port on the active control module can fail over to the same network port on the other (secondary) control module if a network path fails. For example, if Ethernet 0 on CM0 loses connectivity (switch 0 fails), Ethernet 0 on CM1 cache is enabled and utilized. See Dual Controller Configuration on page 16 for details. • Control module failover. In a dual control module array, if the active control module fails, the secondary control module automatically takes over and becomes active. If a cable is connected to a network port on the newly active control module, network I/O can switch to its network interface. Depending on circumstances, network I/O might instead continue through the previously active control module. (For example, the control module that becomes active can use either its own local network interface, or the network interface on the previously active control module.) 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

PS6610
Hardware
Owner's
Manual
3
Control
Module
Maintenance
LED
Name
State
Description
Off
Normal
operation
or
no
power
ERR
Steady
red
Array
is
starting
up,
in
error
condition,
in
Standby
mode,
or
returning
from
Standby
mode.
Blinking
red
Array
is
entering
power
standby
mode
because
the
Standby
On/Off
button
was
pressed.
PWR
Off
On
(steady
green)
No
power
Power/OK
Identify
Control
Module
Failures
You
can
identify
a
failure
in
a
control
module
by:
LEDs
on
the
control
module
itself.
See
Interpreting
Control
Module
LEDs
on
page
16
.
Messages
on
the
console,
in
the
event
log,
or
in
the
Group
Manager
GUI
Alarms
panel.
Group
Manager
GUI
and
CLI
output.
The
Member
Controllers
window
or
the
member
select
show
controllers
command
output
shows
the
control
module
status
not
installed
.
When
viewed
from
the
rear
of
the
array,
CM0
is
on
the
left
and
CM1
is
on
the
right.
If
a
control
module
fails,
contact
your
PS
Series
support
provider
for
a
replacement.
About
Failover
Behavior
In
a
dual
control
module
array,
only
one
control
module
is
active
(processing
network
I/O
and
performing
storage
functions)
at
one
time.
Each
control
module
stores
recently
used
data.
For
redundancy,
the
cache
on
the
secondary
control
module
mirrors
the
data
that
is
stored
in
the
cache
on
the
active
control
module.
The
active
control
module
can
use
the
network
interfaces
of
the
secondary
control
module
for
failover
if
a
cable
is
connected
from
the
corresponding
port
on
the
secondary
control
module
to
a
functioning
network
switch.
Note:
The
management
ports
on
the
control
modules
do
not
fail
over
if
one
control
module
fails.
Therefore,
if
you
are
using
a
dedicated
management
network,
make
sure
the
management
ports
on
both
control
modules
are
connected
to
the
management
network.
A
PS
Series
array
provides
the
following
types
of
network
failure
protection:
Vertical
failover.
In
a
dual
control
module
array,
a
network
port
on
the
active
control
module
can
fail
over
to
the
same
network
port
on
the
other
(secondary)
control
module
if
a
network
path
fails.
For
example,
if
Ethernet
0
on
CM0
loses
connectivity
(switch
0
fails),
Ethernet
0
on
CM1
cache
is
enabled
and
utilized.
See
Dual
Controller
Configuration
on
page
16
for
details.
Control
module
failover.
In
a
dual
control
module
array,
if
the
active
control
module
fails,
the
secondary
control
module
automatically
takes
over
and
becomes
active.
If
a
cable
is
connected
to
a
network
port
on
the
newly
active
control
module,
network
I/O
can
switch
to
its
network
interface.
Depending
on
circumstances,
network
I/O
might
instead
continue
through
the
previously
active
control
module.
(For
example,
the
control
module
that
becomes
active
can
use
either
its
own
local
network
interface,
or
the
network
interface
on
the
previously
active
control
module.)
18