Table 1-34., SEL Commands, Commands, NetFn, Supported, SDR Repository Commands

Page 29 highlights

Table 1-34 shows the SEL commands. Table 1-34. SEL Commands Commands NetFn CMD O/M Get SEL Info Storage 40h M Get SEL Allocation Info Storage 41h O Reserve SEL Storage 42h O Get SEL Entry Storage 43h M Add SEL Entry Storage 44h M Partial Add SEL Entry Storage 45h M Delete SEL Entry Storage 46h O Clear SEL Storage 47h M Get SEL Time Storage 48h M Set SEL Time Storage 49h M Get Auxiliary Log Status Storage 5Ah O Set Auxiliary Log Status Storage 5Bh O NOTE: Support for Partial Add SEL is not required when Add SEL is supported. Table 1-35 shows the SDR repository commands. Table 1-35. SDR Repository Commands Commands NetFn CMD O/M Get SDR Repository Info Storage 20h M Get SDR Repository Allocation Storage 21h O Info Reserve SDR Repository Storage 22h M Get SDR Storage 23h M Add SDR Storage 24h M Partial ADD SDR Storage 25h O Delete SDR Storage 26h O Clear SDR Repository Storage 27h M Get SDR Repository Time Storage 28h O Set SDR Repository Time Storage 29h O Supported Yes No Yes Yes Yes No1 Yes Yes Yes Yes No No Supported Yes No Yes Yes No Yes No Yes Yes Yes Using the Baseboard Management Controller 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Using the Baseboard Management Controller
29
Table 1-34 shows the SEL commands.
NOTE:
Support for
Partial Add SEL
is not required when
Add SEL
is supported.
Table 1-35 shows the SDR repository commands.
Table 1-34.
SEL Commands
Commands
NetFn
CMD
O/M
Supported
Get SEL Info
Storage
40h
M
Yes
Get SEL Allocation Info
Storage
41h
O
No
Reserve SEL
Storage
42h
O
Yes
Get SEL Entry
Storage
43h
M
Yes
Add SEL Entry
Storage
44h
M
Yes
Partial Add SEL Entry
Storage
45h
M
No1
Delete SEL Entry
Storage
46h
O
Yes
Clear SEL
Storage
47h
M
Yes
Get SEL Time
Storage
48h
M
Yes
Set SEL Time
Storage
49h
M
Yes
Get Auxiliary Log Status
Storage
5Ah
O
No
Set Auxiliary Log Status
Storage
5Bh
O
No
Table 1-35.
SDR Repository Commands
Commands
NetFn
CMD
O/M
Supported
Get SDR Repository Info
Storage
20h
M
Yes
Get SDR Repository Allocation
Info
Storage
21h
O
No
Reserve SDR Repository
Storage
22h
M
Yes
Get SDR
Storage
23h
M
Yes
Add SDR
Storage
24h
M
No
Partial ADD SDR
Storage
25h
O
Yes
Delete SDR
Storage
26h
O
No
Clear SDR Repository
Storage
27h
M
Yes
Get SDR Repository Time
Storage
28h
O
Yes
Set SDR Repository Time
Storage
29h
O
Yes