Dell PowerEdge C2100 Using the Baseboard Management Controller - Page 31
Table 1-38., LAN Commands, Commands, NetFn, Supported, PEF/PET Alerting Commands
View all Dell PowerEdge C2100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Table 1-37. Sensory Device Commands Commands Get Sensor Type Set Sensor Reading and Event Status NetFn S/E S/E CMD 2Eh 2Fh Table 1-38 shows the LAN commands. Table 1-38. LAN Commands Commands Set LAN Configuration Parameters (Note: Parameter 9 and 25 are not supported. Get LAN Configuration Parameters (Note: Parameter 9 and 25 are not supported. Suspend BMC ARP Get IP/UDP/RMCP Statistics NetFn Transport Transport Transport Transport CMD 01h 02h 03h 04h Table 1-39 shows the PEF/PET alerting commands. Table 1-39. PEF/PET Alerting Commands Commands Get PEF Capabilities Arm PEF Postpone Timer Set PEF Configuration Parameters Get PEF Configuration Parameters Set Last Processed Event ID Get Last Processed Event ID Alert Immediate PET Acknowledge NetFn S/E S/E S/E S/E S/E S/E S/E S/E CMD 10h 11h 12h 13h 14h 15h 16h 17h O/M Supported O No M Yes O/M Supported M Yes M Yes O No O No O/M Supported M Yes M Yes M Yes M Yes M Yes M Yes M Yes M Yes Using the Baseboard Management Controller 31