Dell PowerEdge C2100 Using the Baseboard Management Controller - Page 7

Component Information, Power Management, System Event Log, Power Control Operation, Apply - memory

Page 7 highlights

Component Information Server Board Information Including Serial Number, BIOS Version, Product ID, Manufacturer and Manufacture Date. CPU Information Including CPU ID, Status, Socket, Manufacturer, Model and Frequency. Memory Information Including Memory ID, Status, Socket, Module Size, Model and Frequency. Power Management This feature enables the administrator to power on or power down the system remotely. Table 1-3. Power Status Power Status Power Status Description Yes or No Select a Power Control Operation. Table 1-4. Power Control Operation Options Power Control Operation Power On System Power Off System Reset System Power Cycle System NMI Soft Shutdown Description Powers on the system. Powers off the system. Reboots system without powering off (warm boot). Powers off, then reboots system (cold boot). Sends Non-Masking Interrupt to halt system operation. Shuts down system. Click Apply to enable the selected Power Control Operation. System Event Log The System Event Log (SEL) page displays system events that occur on the managed system. The SEL is generated by the Baseboard Management Controller (iBMC) or BIOS on the managed system. Using the Baseboard Management Controller 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Using the Baseboard Management Controller
7
Component Information
Server Board Information
Including Serial Number, BIOS Version, Product ID, Manufacturer and Manufacture Date.
CPU Information
Including CPU ID, Status, Socket, Manufacturer, Model and Frequency.
Memory Information
Including Memory ID, Status, Socket, Module Size, Model and Frequency.
Power Management
This feature enables the administrator to power on or power down the system remotely.
Select a
Power Control Operation
.
Click
Apply
to enable the selected
Power Control Operation
.
System Event Log
The System Event Log (SEL) page displays system events that occur on the managed system. The
SEL is generated by the Baseboard Management Controller (iBMC) or BIOS on the managed
system.
Table 1-3.
Power Status
Power Status
Description
Power Status
Yes
or
No
Table 1-4.
Power Control Operation Options
Power Control Operation
Description
Power On System
Powers on the system.
Power Off System
Powers off the system.
Reset System
Reboots system without powering off (warm boot).
Power Cycle
System
Powers off, then reboots system (cold boot).
NMI
Sends Non-Masking Interrupt to halt system operation.
Soft Shutdown