Dell PowerEdge C2100 Using the Baseboard Management Controller - Page 30
Table 1-36., FRU Inventory Device Commands, Commands, NetFn, Supported, SDR Repository Commands
View all Dell PowerEdge C2100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
www.dell.com | support.dell.com Table 1-35. SDR Repository Commands Commands NetFn CMD O/M Enter SDR Repository Update Storage 2Ah O Mode Exit SDR Repository Update Storage 2Bh O Mode Run Initialization Agent Storage 2Ch O Table 1-36 shows the FRU inventory device commands. Table 1-36. FRU Inventory Device Commands Commands NetFn CMD O/M Get FRU Inventory Area Info Storage 10h M Read FRU Inventory Data Storage 11h M Write FRU Inventory Data Storage 12h M Table 1-37 shows the sensory device commands. Table 1-37. Sensory Device Commands Commands NetFn CMD O/M Get Device SDR Info S/E 20h O Get Device SDR S/E 21h O Reserve Device SDR Repository S/E 22h O Get Sensor Reading Factors S/E 23h O Set Sensor Hysteresis S/E 24h O Get Sensor Hysteresis S/E 25h O Set Sensor Threshold S/E 26h O Get Sensor Threshold S/E 27h O Set Sensor Event Enable S/E 28h O Get Sensor Event Enable S/E 29h O Re-arm Sensor Events S/E 2Ah O Get Sensor Event Status S/E 2Bh O Get Sensor Reading S/E 2Ch M Set Sensor Type S/E 2Dh O 30 Using the Baseboard Management Controller Supported No No Yes Supported Yes Yes Yes Supported No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No