Dell PowerEdge M420 Dell PowerConnect M8024-k Release Notes - Page 24

Users can send pure IPv4 pings to the other

Page 24 highlights

Summary Non-configuration file getting loaded to startup-config through HTTP. A v6 ping with the v4 header destination address set to 224.0.0.2 (all routers addr) is not responded to. Certain packets match system rules that elevate the priority for protocol packets. User Impact Switch does not utilize invalid configuration file information. Earlier versions of startup-config are not available for fallback when overwritten with an invalid startup-config. Users are not able to ping over 6to4 tunnels using IPv6 addresses. Workaround In this case, an invalid configuration file was downloaded (on purpose) via the web. When the switch rebooted, it detected that the configuration file was invalid and overwrote the start-up config with the default configuration (an empty configuration). Users are advised to maintain off-line copies of switch configurations. Users can send pure IPv4 pings to the other end of the tunnel. Packets may be transmitted out of order when using priority flow control. Additionally, if the queue that the packets are put on is not enabled for lossless PFC, then the packets can be transmitted even when the port was told to pause. This may have an effect on connections that expect packet order to be maintained, e.g. FCoE. None. 22 System Firmware Version 4.1.0.6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

22
System Firmware Version 4.1.0.6
Summary
User Impact
Workaround
Non-configuration file
getting loaded to
startup-config through
HTTP.
Switch does not utilize invalid configuration file
information. Earlier versions of startup-config
are not available for fallback when overwritten
with an invalid startup-config.
In this case, an invalid configuration file was
downloaded (on purpose) via the web. When
the switch rebooted, it detected that the
configuration file was invalid and overwrote
the start-up config with the default
configuration (an empty configuration). Users
are advised to maintain off-line copies of
switch configurations.
A v6 ping with the v4
header destination
address set to 224.0.0.2
(all routers addr) is not
responded to.
Users are not able to ping over 6to4 tunnels using
IPv6 addresses.
Users can send pure IPv4 pings to the other
end of the tunnel.
Certain packets match
system rules that elevate
the priority for protocol
packets.
Packets may be transmitted out of order when
using priority flow control. Additionally, if the
queue that the packets are put on is not enabled
for lossless PFC, then the packets can be
transmitted even when the port was told to pause.
This may have an effect on connections that
expect packet order to be maintained, e.g. FCoE.
None.