Dell PowerEdge M520 Brocade M5424 Blade Server SAN I/O Module Hardware Referen - Page 13

Ports on Demand (POD), Fabric OS Native and Access Gateway modes

Page 13 highlights

Fabric OS Native and Access Gateway modes 1 NOTE You can also install 4 Gbps SFPs in the SAN I/O Module, however all SFPs must be Brocade-branded. • One serial console port on the front panel (RJ45 connector). • One green/amber LED to indicate status for each port. If dark, the port is unlicensed. • The following system light-emitting diodes (LEDs): - One green power LED to indicate module power-on. - One green/amber LED to indicate module status. - One blue, identify module and flash blue to locate module. See "Interpreting LED activity" on page 22 for details about the SAN I/O Module LEDs. Ports on Demand (POD) The SAN I/O Module ships with a specific number of active ports. You can allocate a POD license to activate additional ports. The SAN I/O Module supports two licensing methods: static and dynamic (module default). • For Dynamic POD, 12 licenses are available for the first 12 active ports. Ports 17 and 18 are licensed at the factory. The remaining 10 licenses are assigned to active ports as required. Once licenses are issued, they can be moved from one port to another, making port licensing more flexible. • For static POD, Table 1 shows the base internal and external ports that are licensed, as well as the additional 12 ports that can be activated with a POD license. For details about activating and deactivating additional ports when you have POD licensing, refer to "Activating Ports on Demand (POD)" on page 17. TABLE 1 Ports available Port Licensing External Ports Internal Ports Base POD 17, 18, 19, and 20 0, 21, 22, and 23 1, 2, 3, 4, 5, 6, 7, and 8 9, 10, 11, 12, 13, 14, 15, and 16 M5424 SAN I/O Module Hardware Reference Manual 3 53-1001082-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

M5424 SAN I/O Module Hardware Reference Manual
3
53-1001082-01
Fabric OS Native and Access Gateway modes
1
NOTE
You can also install 4 Gbps SFPs in the SAN I/O Module, however all SFPs must be
Brocade-branded.
One serial console port on the front panel (RJ45 connector).
One green/amber LED to indicate status for each port.
If dark, the port is unlicensed.
The following system light-emitting diodes (LEDs):
-
One green power LED to indicate module power-on.
-
One green/amber LED to indicate module status.
-
One blue, identify module and flash blue to locate module.
See
“Interpreting LED activity”
on page 22 for details about the SAN I/O Module LEDs.
Ports on Demand (POD)
The SAN I/O Module ships with a specific number of active ports. You can allocate a POD license to
activate additional ports. The SAN I/O Module supports two licensing methods: static and dynamic
(module default).
For Dynamic POD, 12 licenses are available for the first 12 active ports. Ports 17 and 18 are
licensed at the factory. The remaining 10 licenses are assigned to active ports as required.
Once licenses are issued, they can be moved from one port to another, making port licensing
more flexible.
For static POD,
Table 1
shows the base internal and external ports that are licensed, as well as
the additional 12 ports that can be activated with a POD license. For details about activating
and deactivating additional ports when you have POD licensing, refer to
“Activating Ports on
Demand (POD)”
on page 17.
TABLE 1
Ports available
Port Licensing
External Ports
Internal Ports
Base
17, 18, 19, and 20
1, 2, 3, 4, 5, 6, 7, and
8
POD
0, 21, 22, and 23
9, 10, 11, 12, 13, 14,
15, and 16