Dell PowerEdge M520 Brocade M5424 Blade Server SAN I/O Module Hardware Referen - Page 36
Weight and physical dimensions, Facility requirements
View all Dell PowerEdge M520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
A Weight and physical dimensions Weight and physical dimensions Table 6 lists the weight and physical dimensions of the SAN I/O Module. TABLE 6 SAN I/O Module Specifications Dimension Measurements Height Width Depth Weight 1.27 in (32.48 mm) 10.74 in (272.75 mm) 12.09 in (307.24 mm) 4.65 (2.10 kg) - without media Facility requirements The information in Table 7 shows the operating and non-operating limitations of the Brocade M5424 Fibre Channel SAN I/O Module SAN I/O Module. TABLE 7 Condition Environmental Requirements Operating Non-operating Temperature Humidity Altitude Shock Vibration Air flow 32°F to 104°F (0°C to 40°C) -4°F to 158°F (-20°C to 70°C) 10% to 90%, non-condensing at 84.2°F (29°C) 5% to 95%, non-condensing at 100.4 °F (38°C) Up to 10,000 ft (3,048 m) 35,000 ft (10,668 m) 20 G for 6 ms 50G with velocity change of 4216 mm/sec squared 0.4 G at 5-500 Hz for 60 minutes 0.5 G at 2-200 Hz for 15 minutes 86 °F (30°C) Ambient: Approx. 3CFM None required 104°F (40°C) Ambient: Approx. 9CFM 26 M5424 SAN I/O Module Hardware Reference Manual 53-1001082-01