A Weight and physical dimensions Weight and physical dimensions Table 6 lists the weight and physical dimensions of the SAN I/O Module. TABLE 6 SAN I/O Module Specifications Dimension Measurements Height Width Depth Weight 1.27 in (32.48 mm) 10.74 in (272.75 mm) 12.09 in (307.24 mm) 4.65 (2.10 kg) - without media Facility requirements The information in Table 7 shows the operating and non-operating limitations of the Brocade M5424 Fibre Channel SAN I/O Module SAN I/O Module. TABLE 7 Condition Environmental Requirements Operating Non-operating Temperature Humidity Altitude Shock Vibration Air flow 32°F to 104°F (0°C to 40°C) -4°F to 158°F (-20°C to 70°C) 10% to 90%, non-condensing at 84.2°F (29°C) 5% to 95%, non-condensing at 100.4 °F (38°C) Up to 10,000 ft (3,048 m) 35,000 ft (10,668 m) 20 G for 6 ms 50G with velocity change of 4216 mm/sec squared 0.4 G at 5-500 Hz for 60 minutes 0.5 G at 2-200 Hz for 15 minutes 86 °F (30°C) Ambient: Approx. 3CFM None required 104°F (40°C) Ambient: Approx. 9CFM 26 M5424 SAN I/O Module Hardware Reference Manual 53-1001082-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

26
M5424 SAN I/O Module Hardware Reference Manual
53-1001082-01
Weight and physical dimensions
A
Weight and physical dimensions
Table 6
lists the weight and physical dimensions of the SAN I/O Module.
Facility requirements
The information in
Table 7
shows the operating and non-operating limitations of the Brocade
M5424 Fibre Channel SAN I/O Module
SAN I/O Module.
TABLE 6
SAN I/O Module Specifications
Dimension
Measurements
Height
1.27 in (32.48 mm)
Width
10.74 in (272.75 mm)
Depth
12.09 in (307.24 mm)
Weight
4.65 (2.10 kg) — without media
TABLE 7
Environmental Requirements
Condition
Operating
Non-operating
Temperature
32°F to 104°F (0°C to 40°C)
-4°F to 158°F (-20°C to 70°C)
Humidity
10% to 90%, non-condensing at
84.2°F (29°C)
5% to 95%, non-condensing at
100.4 °F (38°C)
Altitude
Up to 10,000 ft (3,048 m)
35,000 ft (10,668 m)
Shock
20 G for 6 ms
50G with velocity change of 4216
mm/sec squared
Vibration
0.4 G at 5-500 Hz
for 60 minutes
0.5 G at 2-200 Hz for 15 minutes
Air flow
86 °F (30°C) Ambient: Approx. 3CFM
104°F (40°C) Ambient: Approx.
9CFM
None required