Dell PowerEdge M520 Brocade 4424 Blade Server SAN I/O Module Hardware Referenc - Page 35
Dell PowerEdge M520 Manual
View all Dell PowerEdge M520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Appendix SAN I/O Module specifications A This appendix provides product specifications and regulatory compliance as a handy reference. Access Gateway Mode default port mapping The 4424 SAN I/O Module can contain 24 total ports. Of these, F_Ports are ports 1-16 and N_Ports are ports 0 and 17-23. In Access Gateway mode, the SAN I/O Module F_Ports are mapped to N_Ports. This following lists the factory-default F_Port to N_Port mapping for Access Gateway mode. Since the SAN I/O Module is shipped with Dynamic Ports on Demand (DPOD) enabled, any out of the 24 ports can be enabled. Therefore this mapping applies for 12 active ports or, if POD licensing is enabled, for 24 ports. For more information on changing port mapping and managing ports in Access Gateway Mode, refer to the Access Gateway Administrator's Guide. 17-20 as N_Port with failover enabled, failback enabled 0, 21-23 as N_Port with failover enabled, failback enabled 1, 2 mapped to 17 3, 4 mapped to 18 5, 6 mapped to 19· 7, 8 mapped to 20 9, 10 mapped to 21· 11, 12 mapped to 22· 13, 14 mapped to 23· 15, 16 mapped to 0 Processor and memory specifications The processor and memory installed in the SAN I/O Module are shown in Table 5. TABLE 5 Memory Type Memory Specifications Value 333 MHz 256 MB - for system memory at 64 bits wide with 8 ECC bits 4 MB 256 MB PowerPC 440GP processor SDRAM Boot flash Compact flash 4424 Blade Server SAN I/O Module Hardware Reference Manual 53-0000571-01 25