Dell PowerEdge M710HD Fabric OS Message Reference - Page 160
C2-1006, C2-1007, C2-1008
View all Dell PowerEdge M710HD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
11 C2-1006 C2-1006 Message Message , [C2-1006], ,, WARNING, , ,: Internal link errors reported, no hardware faults identified, continuing monitoring: fault1:, fault2: thresh1:0x. Probable Cause Indicates a warning that some internal link errors have been detected. These can be normal in an active running system. The system will now automatically start a more detailed monitoring of internal hardware reported errors. There is no action required by the user at this time. If any actual hardware failures are detected, a C2-1010 log will be generated identifying the failing FRU. Recommended No action is required. Action Severity WARNING C2-1007 Message Message , [C2-1007], ,, WARNING, , S , P (): best effort QOS will be turned off at next port state change as it is not supported under this configuration. Probable Cause Indicates QoS will be turned off automatically at the next port state change since best effort is no longer supported on a 4G platform or 8G platform long distance port. Recommended No action is required. Action Severity WARNING C2-1008 Message Message , [C2-1008], ,, WARNING, , , : QOS overwrites portcfglongdistance vc_translation_link_init. ARB will be used on the link. Probable Cause Indicates QoS overwrites the portcfglongdistance vc_translation_link_init 0 choice. ARB will be used on the link. Recommended No action is required. Action Severity WARNING 84 Fabric OS Message Reference 53-1001767-01