Dell PowerEdge M710HD Fabric OS Message Reference - Page 753
AUDIT AN System Messages, AN-1003
View all Dell PowerEdge M710HD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 753 highlights
AUDIT AN System Messages Chapter 113 AN-1003 Message , [AN-1003], ,, WARNING, , Slot , port is a latency bottleneck. percent of last seconds were affected by this condition. Probable Cause For an F_Port, it indicates that the attached device is slow in responding to frames going out of this port. This latency may be inherent in the device or due to heavy workload on the device. For an E_Port, it indicates a downstream primary bottleneck. Recommended Find the Top Talkers in the egress direction from this port and apply Ingress Rate Limiting to one or Action more of them. Severity WARNING AN-1004 Message , [AN-1004], ,, WARNING, , Slot , port is a congestion bottleneck. percent of last seconds were affected by this condition. Probable Cause Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link. Recommended Add more capacity on the path, using trunk links if possible. Action Severity WARNING AN-1005 Message , [AN-1005], ,, WARNING, , Slot , port has bottleneck cleared. Probable Cause Indicates that the bottleneck was cleared on the port. Recommended No action is required. Action Severity WARNING Fabric OS Message Reference 677 53-1001767-01