35 FICN-1070 Recommended If resolution of the configuration issue cannot be completed, contact your vendor's customer Action support for assistance. Severity ERROR FICN-1070 Message , [FICN-1070], ,, INFO, , DevTapeIngr:Exceptional Status rcvd on Path= state=0x status=0x. Probable Cause Indicates the normal end of tape status (0x0D or 0x05) is received from the device or error status (including Unit Check 0x02) is received from an active emulation device. Recommended The end of tape is a normal event during pipelining and not the unit check. If there are associated Action IO error messages with this event, please contact your vendor's customer support for assistance. Severity INFO FICN-1071 Message , [FICN-1071], ,, INFO, , HostTapeIngr:Tape Loaded on Path= . Probable Cause Indicates the tape IOs are processed from a locally connected LPAR, which indicates that a tape is loaded on a device. Recommended No action is required. Action Severity INFO FICN-1072 Message , [FICN-1072], ,, INFO, , DevTapeEgr:Tape Loaded on Path= . Probable Cause Indicates the tape IOs are processed from a locally connected LPAR, which indicates that a tape is loaded on a device. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 259 53-1001767-01