Dell PowerVault 51F Dell PowerVault 51F 8-Port Fibre Channel Switch Insta - Page 140
Error Messages by Firmware Module, A-1., errShow Command Example, Table A-1., Errors
View all Dell PowerVault 51F manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 140 highlights
=> errShow Error 02 -------0x103dc470 (tSilkworm): Apr 9 10:41:06 Error SENSOR-FAILED, 3, sensor 7 (Fan 2) is below minim Type to continue, Q to stop: Error 01 -------0x103dc470 (tSilkworm): Apr Error DIAG-TIMEOUT, 1, Port 2 receive timeout. 9 10:40:51 Type to continue, Q to stop: value = 1 = 0x1 Figure A-1. errShow Command Example To display error messages via Telnet: 1. From the prompt, type errShow. 2. To scroll through the error list, type CR. 3. Scroll through the error log (if no errors were encountered, the message No Error appears). Error Messages by Firmware Module Table A-1 shows the error messages organized by module. Table A-1. Errors Module Error Severity Flood INVLSR (3) Explanation An unknown Link State Record has been received from a neighbor switch. Action Check that all paths and routing tables are correct using the commands uPathShow , or uPathAllShow. If the paths are not correct reboot the neighbor switch that sent the wrong data. Check the paths and routes again. If they are still incorrect, reboot the local switch. A-2 Installation and Troubleshooting Guide