Dell PowerVault NX3100 Hardware Owner's Manual - Page 33
in BIOS. The BIOS setting, Sparing mode. See System
View all Dell PowerVault NX3100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Message Causes Sector not found. Faulty hard drive, USB Seek error. device, or USB medium. Seek operation failed. Shutdown failure. General system error. Sparing mode disabled. For sparing mode, matched sets of three must be populated across slots. The memory configuration does not match the setting in BIOS. The BIOS setting has been disabled. The amount of Memory has been added or system memory has removed or a memory changed. module may be faulty. Corrective Actions Replace the USB medium or device. Ensure that the USB or SAS backplane cables are properly connected. See "Troubleshooting a USB Device" on page 130 or "Troubleshooting a Hard Drive" on page 140 for the appropriate drive(s) installed in your system. See "Getting Help" on page 157. Reconfigure the memory modules for Memory Sparing mode. See "System Memory" on page 82. If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 137. About Your System 33