Dell S4148U-ON Open Networking Hardware Diagnostic Guide June 2018 - Page 53

Rev 0x11, Chip BCM88375_B0, Connect two ports to IXIA with SFP+ optics and cables.

Page 53 highlights

Connect all the ports with the SFP+ optics with TX and RX shorted. • nputool -i -t 5 -T cpu_self • nputool --init --test 5 --traffic cpu_self CPU traffic for uplink ports connected between adjacent ports Traffic is sent from the CPU internally generated packet to the front-end Dell EMC SFP+ ports which are connected with SFP+ optics using a cable. Connect the SFP+ ports with the Dell EMC SFP+ optics using cables. • nputool -i -t 5 -T cpu_adj • nputool --i --test 5 --traffic cpu_adj IXIA traffic with external loopback Traffic is sent from the CPU internally generated packet to the front-end SFP+ ports which are connected with the Dell EMC SFP+ optics using a cable. Connect the first port to IXIA and all other ports with Loopback optics. • nputool -i -t 5 -T ixia_self -d • nputool --init --test 5 --traffic ixia_self -d Configure the VLAN and display the BCM.0> shell. To verify the counters, use the show c command in the BCM shell. IXIA traffic with adjacent ports connected to IXIA Traffic is sent from the CPU internally generated packet to the front-end ports which are connected with DACs or optics using cables connected top-to-bottom. Connect two ports to IXIA with SFP+ optics and cables. • nputool -i -t 5 -T ixia_adj • nputool --init --test 5 --traffic ixia_adj Configure the VLAN and display the BCM.0> shell. To verify the counters, use the show c command in the BCM shell. PRBS for QSFP ports Connect ports with Loopback cables and run the PRBS MAC and EXT Loopback tests. • PRBS MAC level test nputool -i -t 2 or nputool --init --test 2 • PRBS EXT level test nputool -i -t 3 or nputool --init --test 3 For example: root@dell-diag-os:~# nputool --init --test 2 DMA pool size: 16777216 PCI unit 0: Dev 0x8375, Rev 0x11, Chip BCM88375_B0, Driver BCM88375_B0 sysconf_probe successful global_sal_config successful *** 1 BCM devices are detected Diag NPU initialization over Test link_status_test for NPU 0 SKIPPED

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

Connect all the ports with the SFP+ optics with TX and RX shorted.
nputool -i -t 5 -T cpu_self
nputool --init --test 5 --traffic cpu_self
CPU
traffic
for uplink ports connected between adjacent ports
Traffic
is sent from the CPU internally generated packet to the front-end Dell EMC SFP+ ports which are connected with SFP+ optics
using a cable.
Connect the SFP+ ports with the Dell EMC SFP+ optics using cables.
nputool -i -t 5 -T cpu_adj
nputool --i --test 5 --traffic cpu_adj
IXIA
traffic
with external loopback
Traffic
is sent from the CPU internally generated packet to the front-end SFP+ ports which are connected with the Dell EMC SFP+ optics
using a cable.
Connect the
first
port to IXIA and all other ports with Loopback optics.
nputool -i -t 5 -T ixia_self -d
nputool --init --test 5 --traffic ixia_self -d
Configure
the VLAN and display the
BCM.0>
shell. To verify the counters, use the
show c
command in the BCM shell.
IXIA
traffic
with adjacent ports connected to IXIA
Traffic
is sent from the CPU internally generated packet to the front-end ports which are connected with DACs or optics using cables
connected top-to-bottom.
Connect two ports to IXIA with SFP+ optics and cables.
nputool -i -t 5 -T ixia_adj
nputool --init --test 5 --traffic ixia_adj
Configure
the VLAN and display the
BCM.0>
shell. To verify the counters, use the
show c
command in the BCM shell.
PRBS for QSFP ports
Connect ports with Loopback cables and run the PRBS MAC and EXT Loopback tests.
PRBS MAC level test
nputool –i –t 2
or
nputool --init --test 2
PRBS EXT level test
nputool –i –t 3
or
nputool --init --test 3
For example:
root@dell-diag-os:~# nputool --init --test 2 DMA pool size: 16777216 PCI unit 0: Dev 0x8375,
Rev 0x11, Chip BCM88375_B0,
Driver BCM88375_B0 sysconf_probe successful global_sal_config successful ***
1 BCM devices are detected Diag NPU initialization over
Test link_status_test for NPU 0
................
SKIPPED <<<---
Test snake_traffic_test for NPU 0
..............
SKIPPED <<<---
Test prbs_mac_test for NPU 0
...................
Passed
Test prbs_ext_test for NPU 0
...................
SKIPPED <<<---
Test uplink_link_status_test for NPU 0
.........
SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0
.......
SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0
............
SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0
............
SKIPPED <<<---
NPU tests
......................................
Passed
Dell EMC DAIG-OS tools
53