Dell S5212F-ON Open Networking Hardware Diagnostic Guide December 2021 - Page 50

CPU traffic with external loopback for uplink ports SFP, IXIA traffic with external loopback

Page 50 highlights

Test link_status_test for NPU 0 SKIPPED

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

Test link_status_test for NPU 0
.............
SKIPPED <<<---
Test snake_traffic_test for NPU 0
.............
Passed
Test prbs_mac_test for NPU 0
.............
SKIPPED <<<---
Test prbs_ext_test for NPU 0
.............
SKIPPED <<<---
Test uplink_link_status_test for NPU 0
.............
SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0
.............
SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0
.............
SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0
.............
SKIPPED <<<---
NPU tests
...........................................
Passed
root@dell-diag-os:~#
IXIA traffic with external loopback
Tests the traffic sent from IXIA to port-1 and to the front-end ports which are connected with external Loopback optics.
Connect the first port to IXIA and all other ports with QSFP28 Loopback optics.
nputool -i -t 1 -T ixia_self -d
nputool --init --test 1 --traffic ixia_self -d
These commands configure the virtual local area network (VLAN) and after the
BCM.0>
shell displays, send the traffic from
IXIA. To verify the counters, run the
show c
command in the BCM shell. For the S5148F-ON switch, to verify the counters, run
the
show c
command in the XP Shell.
IXIA traffic with adjacent loopback
Tests the traffic sent from IXIA to the front-end ports which are connected with DACs or optics with cables connected
top-to-bottom.
Connect the first two ports to IXIA and all the remaining ports with DACs or 40G/100G optics with cables.
nputool –i –t 1 –T ixia_adj
nputool --init --test 1 --traffic ixia_adj
The previous commands configure the VLAN and after the
BCM.0>
shell displays. To verify the counters, run the
show c
command in the BCM shell. For the S5148F-ON switch, to verify the counters, run the
show c
command in the XP Shell.
CPU traffic with external loopback for uplink ports (SFP+)
Traffic is sent from the CPU to the SFP+ ports.
Connect all the ports with the SFP+ optics with TX and RX shorted.
nputool -i -t 5 -T cpu_self
nputool --init --test 5 --traffic cpu_self
CPU traffic for uplink ports connected between adjacent ports
Traffic is sent from the CPU internally generated packet to the front-end Dell EMC SFP+ ports which are connected with SFP+
optics using a cable.
Connect the SFP+ ports with the Dell EMC SFP+ optics using cables.
nputool -i -t 5 -T cpu_adj
nputool --i --test 5 --traffic cpu_adj
IXIA traffic with external loopback
Traffic is sent from the CPU internally generated packet to the front-end SFP+ ports which are connected with the Dell EMC
SFP+ optics using a cable.
Connect the first port to IXIA and all other ports with Loopback optics.
nputool -i -t 5 -T ixia_self -d
nputool --init --test 5 --traffic ixia_self -d
Configure the VLAN and display the
BCM.0>
shell. To verify the counters, use the
show c
command in the BCM shell. For the
S5148F-ON switch, to verify the counters, run the
show c
command in the XP Shell.
IXIA traffic with adjacent ports connected to IXIA
Traffic is sent from the CPU internally generated packet to the front-end ports which are connected with DACs or optics using
cables connected top-to-bottom.
Connect two ports to IXIA with SFP+ optics and cables.
50
Dell EMC DAIG-OS tools