Epson C32C824151 Technical Reference - Page 78
Internal Parameter Setting Methods
![]() |
UPC - 000054074415
View all Epson C32C824151 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
5.5.5.2 Internal Parameter Setting Methods 1. Using the exclusive utility. 2. Using a browser 3. Using arp and ping commands (only to set IP address) 5.5.5.3 Setting with Exclusive utility Settings cannot be made by the specified application software when the ENPC protocol is used. A dedicated utility which can set miscellaneous with the ENPC protocol is provided by EPSON. 5.5.5.4 Setting with Browser Setting can be made by an HTTP browser when connected to the module. The new IP address takes effect when the printer power is turned off and back on. 5.5.5.5 Setting the IP Address with arp + ping This function is available when it has been enabled. The setting can be made from a host in the same segment as the module. The host must support both arp and ping commands. The new IP address takes effect when the module responds to the ping command. Example-1: using SunOS arp -s 123.456.789.123 00:00:48:06:00:01 temp ping 123.456.789.123 Example-2: using Windows arp -s 123.456.789.123 00-00-48-06-00-01 ping 123.456.789.123 5.5.5.6 How to check the Mac Address The Mac address of the UB-E02 can be checked with any of the following methods: ❏ Printing the status sheet ❏ Checking the label on the UB-E02 ❏ Checking the HTTP browser ❏ Checking the printer self-test (however, the self-test function is limited for each model.) 5-8 Specifications Rev. A