Epson DM-D210 Technical Reference Guide - Page 29
DIP Switch 1 Functions, DSW1 No., Function, Default Setting, SW1-5, Transfer Speed bps
![]() |
View all Epson DM-D210 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Chapter 2 Setup DIP Switch 1 Functions The following explains the DIP switch functions. DSW1 No. Function ON OFF 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 *2 1-10 *2 Received Error Data Ignore Receive Data Length Parity Parity Selection Communication Speed Switching Execute Self-Test *1 Not used Ignore 7 bit With Parity Even "?" Display 8 bit No Parity Odd Refer to " Transfer Speed Switching" Yes No Fixed to OFF 1 Executes the self-test once only when the power is turned on. 2 This is not available for the specifications model that has the dip switch with 8 poles. Default Setting OFF OFF OFF OFF ON OFF ON OFF 2 Transfer Speed Switching SW1-5 SW1-6 ON ON OFF ON ON OFF OFF OFF ON ON OFF ON ON OFF OFF OFF 1 Default Setting 2 Settings when connecting using a serial (USB controlled) SW1-7 ON ON ON ON OFF OFF OFF OFF Transfer Speed (bps) 2400 4800 9600 *1 19200 *2 38400 57600 115200 (Reserved) 29
![](/manual_guide/products/epson-dmd210-technical-reference-guide-3736e41/29.png)