Chapter 2 Setup Setting the DP-110 Connector installation screw Inch-type hexagonal lock screws are installed in the connector for serial cable connection of DP-110. If millimeter-type lock screws are needed, use the millimeter-type lock screws of the accessory. Notch (one or more lines) inch-type millimeter-type Installation screw Jumper setting Set the jumpers as follows: JP1 JP2 Description 2 1-2 1-2 For connecting both the TM printer and the DP-110. (Default setting) 2-3 2-3 Set this when using a standalone connection. 32
![](/manual_guide/products/epson-dmd210-technical-reference-guide-3736e41/32.png)
32
Chapter 2
Setup
2
Setting the DP-110
Connector installation screw
Inch-type hexagonal lock screws are installed in the connector for serial cable connection of DP-110.
If millimeter-type lock screws are needed, use the millimeter-type lock screws of the accessory.
Jumper setting
Set the jumpers as follows:
JP1
JP2
Description
1-2
1-2
For connecting both the TM printer and the DP-110. (Default setting)
2-3
2-3
Set this when using a standalone connection.
Notch (one or more lines)
inch-type
millimeter-type
Installation screw