Epson TM-L500A Technical Reference Guide: RFID - Page 49
AEA error judgement for wrong coupon type, Font compatible mode, Truncate function
View all Epson TM-L500A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Chapter 2 Setup AEA error judgement for wrong coupon type • AEA error • No AEA error (initial setting) Font compatible mode • PECTAB-compliant font • IER506-compatible font (initial setting) Truncate function • Does not truncate • Truncates (no error) (initial setting) • Truncates (error) Transmission conditions for serial interface 2 Transmission speed When DIP switches 3 and 4 are set to ON, the value (initially 19200 bps) can be set to 2400, 4800, 9600, 19200, 38400, 57600, or 115200 bps. (See "Transmission Speed (DIP Switches 3/4)" on page 38.) The transmission speed can be set with DIP switches 3 and 4 (See "Transmission Speed (DIP Switches 3/4)" on page 38.) or the memory switch. When DIP switches 3 and 4 are set to ON, the setting with the memory switch is enabled. Parity bit • None (initial setting) • Odd • Even Flow control • RTS/CTS control (initial setting) • DTR/DSR control 49