GAS BURNER DATA TABLES RFA-244 DF Burner Auxiliary Semi-Rapid Dual Burner Position Front R Rear L & R Front L Injector diam. [mm.] 1.10 0.70 1.29 0.80 0.99*5 0.56*5 Gas Type NG LP (Propane) NG LP (Propane) NG LP (Propane) Pressure [i.w.c.] 4" 10" 4" 10" 4" 10" RFA-365 DF Burner Position Auxiliary Front R Semi-Rapid Rear L & R Rapid Front L Dual Burner Centre Injector diam. [mm.] 1.10 0.70 1.29 0.80 1.45 0.91 0.99*5 0.56*5 Gas Type NG LP (Propane) NG NG NG LP (Propane) NG LP (Propane) Pressure [i.w.c.] 4" 10" 4" 10" 4" 10" 4" 10" Rate [BTU/h] 4967 4879 7055 6472 17882 15586 Rate [BTU/h] 4967 4879 7055 6472 8500 8462 17882 15586 17
17
GAS BURNER DATA TABLES
RFA-244 DF
Burner
Position
Injector
Gas
Pressure
Rate
diam. [mm.]
Type
[i.w.c.]
[BTU/h]
Auxiliary
Front R
1.10
NG
4”
4967
0.70
LP (Propane)
10”
4879
Semi-Rapid
Rear L & R
1.29
NG
4”
7055
0.80
LP (Propane)
10”
6472
Dual Burner
Front L
0.99*5
NG
4”
17882
0.56*5
LP (Propane)
10”
15586
RFA-365 DF
Burner
Position
Injector
Gas
Pressure
Rate
diam. [mm.]
Type
[i.w.c.]
[BTU/h]
Auxiliary
Front R
1.10
NG
4"
4967
0.70
LP (Propane)
10”
4879
Semi-Rapid
Rear L & R
1.29
NG
4”
7055
0.80
NG
10”
6472
Rapid
Front L
1.45
NG
4”
8500
0.91
LP (Propane)
10”
8462
Dual Burner
Centre
0.99*5
NG
4”
17882
0.56*5
LP (Propane)
10”
15586