Fisher and Paykel DE70FA1 Dryers DE70FA* & DG70FA* User Guide (English, Sp - Page 11
Location Requirements
View all Fisher and Paykel DE70FA1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Location Requirements US CA The area in which the dryer is located must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids. A dryer produces combustible lint so the area around the dryer must be cleaned regularly to keep it free of lint. Alcove or Closet Installation WARNING When installing a dryer in a closet/alcove it must be exhausted to the outdoors. No other fuel burning appliance can be installed in the same closet or alcove. The total ventilation area must be a minimum of 387cm2 (60 sq. in.) of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 774cm2 (120 sq. in.) of open area equally distributed. The openings must never be obstructed (a louvered door with the minimum air opening is acceptable). Minimum installation clearances are required but more clearance is recommended. minimum clearance required 1430mm (56 25mm (1") 25mm (1") 25mm (1") min 50mm (2") min 76mm (3") total ventilation area 774cm2 (120 in. sq.) 11