Foxconn M61PMX English Manual. - Page 76

Create RAID 1 Mirroring, Mirroring

Page 76 highlights

Create RAID 1 (Mirroring) 1. Select "Mirroring" from the RAID Mode. 5 MediaShield Utility Aug 21 2006 - Define a New Array - RAID Mode: Mirroriendg Stripe Block: Optimal Free Disks Port Disk Model Capacity Array Disks Port Disk Model Capacity 10.10 SWTD3C32W06D2102A0S0JD-9 211918.709GB 1.0 Hitachi HDT725 232.88GB [+] Add [-] Del [ESC] Quit [F6] Back [F7] Finish [TAB] Navigate [↑↓] Select [ENTER] Popup 2. Select two hard disks to build our RAID1 system. 3. Press [TAB] to navigate to left drive panel, then use [→] and [↓] keys to add the hard disks to the right drive panel. MediaShield Utility Aug 21 2006 - Define a New Array - RAID Mode: Mirroriendg Stripe Block: Optimal Free Disks Port Disk Model Capacity Array Disks Port Disk Model Capacity 1.0 ST332060AS 1.0 Hitachi HDT725 [+] Add 298.09GB 232.88GB [-] Del [ESC] Quit [F6] Back [F7] Finish [TAB] Navigate [↑↓] Select [ENTER] Popup 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

5
69
Create RAID 1 (Mirroring)
1. Select “
Mirroring
” from the RAID Mode.
2. Select two hard disks to build our RAID1 system.
3. Press [TAB] to navigate to left drive panel, then use [→] and [↓] keys to add the hard
disks to the right drive panel.
MediaShield Utility
Aug 21 2006
- Define a New Array -
RAID Mode: Mirrored
Stripe Block:
Free Disks
Array Disks
Port
Disk Model
Capacity
Port Disk Model
Capacity
[+] Add
[-] Del
[ESC] Quit
[F6] Back
[F7] Finish
[TAB] Navigate
[↑↓] Select
[ENTER] Popup
Optimal
1.0
Hitachi HDT725
232.88GB
Mirroring
1.1 ST3320620AS
298.09GB
MediaShield Utility
Aug 21 2006
- Define a New Array -
RAID Mode: Mirrored
Stripe Block:
Free Disks
Array Disks
Port
Disk Model
Capacity
Port Disk Model
Capacity
[+] Add
[-] Del
[ESC] Quit
[F6] Back
[F7] Finish
[TAB] Navigate
[↑↓] Select
[ENTER] Popup
Optimal
1.0
Hitachi HDT725
232.88GB
Mirroring
1.0 ST332060AS
298.09GB