    C141-E252-01EN MBA3300RC MBA3147RC MBA3073RC HARD DISK DRIVES PRODUCT MANUAL
  • Fujitsu MBA3147RC | Product Manual - Page 2
    While FUJITSU has sought to ensure the accuracy of all information in this manual, FUJITSU assumes instructions contained herein; including any liability for incidental or consequential damages arising therefrom. FUJITSU DISCLAIMS ALL WARRANTIES controls, medical devices for life support, or weapons
  • Fujitsu MBA3147RC | Product Manual - Page 3
    Edition Date published 01 June, 2007 REVISION RECORD Revised contents Specification No.: C141-E252-**EN C141-E252
  • Fujitsu MBA3147RC | Product Manual - Page 4
    Rev. 24 SCSI Architecture Model-2 (SAM-2) T10/1561D Rev. 14 SCSI Architecture Model-3 (SAM-3) T10/1562D Rev. 05 Serial Attached SCSI (SAS) T10/1601D Rev. 10 Serial Attached SCSI Model-1.1 (SAS 1.1) *1 ANSI = American National Standard Institute In case of conflict between this manual and any
  • Fujitsu MBA3147RC | Product Manual - Page 5
    Preface This manual describes MBA3300RC, MBA3147RC, and MBA3073RC 3.5 - inch hard disk drives with an embedded Serial Attached SCSI (SAS). This manual details the specifications and functions of the above disk drive, and gives the requirements and procedures for installing it into a host computer
  • Fujitsu MBA3147RC | Product Manual - Page 6
    MANUAL MBA3300RC, MBA3147RC, and MBA3073RC are described as "HDD" in this manual. Decimal number is represented normally. Hexadecimal number is represented as X'17B9', 17B9h or 17B9H. Binary number is represented as "010". Conventions for Alert Messages This manual does not perform the product
  • Fujitsu MBA3147RC | Product Manual - Page 7
    spindle motor to stop completely. 2) Then, dismount the HDD using the drive mounting/dismounting mechanism, etc. of the system. When removing the HDD, avoid exposing it to shock or vibration. Just in case, stop dismounting once when SAS connector breaks off contact and wait until the spindle motor
  • Fujitsu MBA3147RC | Product Manual - Page 8
    HDD to other media before requesting repair. Fujitsu does not assume responsibility if data is corrupted during servicing 69 or repair. High temperature To prevent injury, never touch the HDD device. • Never use a conductive cleaner to clean the HDDs. • Never remove any labels from the HDD or
  • Fujitsu MBA3147RC | Product Manual - Page 9
    MANUAL ORGANIZATION PRODUCT MANUAL (This manual) SAS INTERFACE MANUAL 1. General Description 2. Specifications 3. Data Format 4. Installation Requirements 5. Installation 6. Diagnostics and Maintenance 7. Error Analysis 1. SAS Interface 2. Command Processing 3. Data Buffer Management 4. Command
  • Fujitsu MBA3147RC | Product Manual - Page 10
    This page is intentionally left blank.
  • Fujitsu MBA3147RC | Product Manual - Page 11
    CONTENTS Preface ...1 Important Alert Items 3 MANUAL ORGANIZATION 5 CHAPTER 1 General Description 13 1.1 Standard Features 13 1.2 Hardware Structure 17 1.3 System Configuration 18 CHAPTER 2 Specifications 19 2.1 Hardware Specifications 19 2.1.1 Model name and order number 19 2.1.2 Function
  • Fujitsu MBA3147RC | Product Manual - Page 12
    Power Supply Requirements 48 4.3 Connection Requirements 50 4.3.1 Connector location 50 4.3.2 Interface connector 51 4.3.3 Ready LED output signal 53 4.3.4 Connector requirements 53 CHAPTER 5 Installation 55 5.1 Notes on Handling HDDs 55 5.2 Setting ...57 5.2.1 Port Address 57 5.3 Mounting
  • Fujitsu MBA3147RC | Product Manual - Page 13
    Troubleshooting 74 6.4.1 Outline of troubleshooting procedures 74 6.4.2 Troubleshooting with HDD replacement in the field 74 6.4.3 Troubleshooting at the repair site 76 6.4.4 Troubleshooting 44-xx 84 7.2.3 Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00): Disk read error............84 C141-E252 9
  • Fujitsu MBA3147RC | Product Manual - Page 14
    Contents Glossary 7.2.4 Sense data (5-2x-xx), (B-47-xx), (B-4B-xx) and (B-4E-00): interface error 84 ...85 Abbreviation ...87 Index ...89 10 C141-E252
  • Fujitsu MBA3147RC | Product Manual - Page 15
    SAS system configuration (Dual port internal cabled environment 18 Example of SAS Figure 4.1 Dimensions 42 Figure 4.2 HDD orientations 43 Figure 4.3 Mounting frame AC noise filter 50 Figure 4.9 Connector location 50 Figure 4.10 SAS plug connector overview 51 Figure 4.11 Recommended external
  • Fujitsu MBA3147RC | Product Manual - Page 16
    and maximum temperature ....... 46 Table 4.2 Interface connector (SAS plug) signal allocation:CN1 52 Table 4.3 Recommended connectors 53 Table 6.1 Self-diagnostic functions 65 Table 6.2 System-level field troubleshooting 75 Table 6.3 HDD troubleshooting 76 Table 7.1 Definition of sense data
  • Fujitsu MBA3147RC | Product Manual - Page 17
    This chapter describes the feature and configuration of the MBA3xxxRC. The HDDs are high performance large capacity 3.5-inch hard disk drives with an embedded Serial Attached SCSI (SAS) controller. The interface used to connect the HDDs to the host system complies with ANSI T10/1601-D Serial
  • Fujitsu MBA3147RC | Product Manual - Page 18
    SAS to support dual SAS port connection. On the HDDs, Primary and Secondary Ports on SAS plug connector (2 physical links plus power connections) are used for SAS port connection. (5) High-speed data transfer The maximum data-transfer speed on the SAS is 300.0 MB/s. The large-capacity data buffer
  • Fujitsu MBA3147RC | Product Manual - Page 19
    buffer. The initiator software is released from the complicated error recover processing by these error recovery functions of the HDDs. (12) Automatic alternate block reassignment If a defective data block is detected during read or write the HDDs rate increase 1. The drive format at factory shipment
  • Fujitsu MBA3147RC | Product Manual - Page 20
    Using the SAS primitive or the SCSI command, the host system can start and stop the spindle motor. (18) Diagnosis The HDDs have a diagnostic capability which checks internal controller functions and HDD operations. Also, for early detection of and recovery from the errors on the disk, the HDD has
  • Fujitsu MBA3147RC | Product Manual - Page 21
    HDDs have a disk enclosure (DE) and a printed circuit board assembly (PCBA). The DE includes heads on an actuator and disks on a spindle motor mounted on the DE. The PCBA includes a read/write circuit and a controller circuit. (1) Disks The disks head IC that supports high-speed transmission and an
  • Fujitsu MBA3147RC | Product Manual - Page 22
    has a unique address (SAS address). SAS addresses are in the Name Address Authority (NAA) IEEE Registered format defined by SCSI Primary Command-2 (SPC-2). An SAS address consists of 8 bytes as a unique value set for each device. The initiator can implement an I/O operation on an HDD by using the
  • Fujitsu MBA3147RC | Product Manual - Page 23
    reinitializing with the user's system. Table 2.1 Model names and order numbers Model name Order number Interface type Capacity (user area) MBA3300RC CA06778-B400 SAS 300 GB (*) MBA3147RC CA06778-B200 SAS 147 GB (*) MBA3073RC CA06778-B100 SAS 73.5 GB (*) (*) One gigabyte (GB) = one
  • Fujitsu MBA3147RC | Product Manual - Page 24
    Power consumption (*5) Data transfer Internal rate (*6) External Logical data block length Related standards Data buffer Acoustic noise (Idle) Specification MBA3300RC MBA3147RC MBA3073RC 300 GB (*2) 147 GB (*2) 73.5 GB (*2) 4 2 1 8 4 2 82604 cyl typ. (standard format including
  • Fujitsu MBA3147RC | Product Manual - Page 25
    Specifications the HDDs are ready, and the stop time is the time for disks to completely stop from power off or stop command. (*5) This value indicates in idle mode. Power supply at nominal voltage ±1%. 25°C ambient. (*6) The maximum data transfer rate may be restricted to the response speed
  • Fujitsu MBA3147RC | Product Manual - Page 26
    Specifications (*8) The eye mask is as follows: Absolute amplitude [V] Normalized time [U1] Parameter 2xZ2 2xZ1 X1 X2 Unit mVp-p mVp-p UI UI 1.5Gbps 1,600 325 0.275 0.5 3.0Gbps 1,600 275 0.275 0.5 (*9) 1 MB = 1,048,576 bytes. 22 C141-E252
  • Fujitsu MBA3147RC | Product Manual - Page 27
    Ready (average) Spin up Power requirement (*5) +12V DC Peak operating current Maximum (peak) DC (*6) Peak operating current DC (reference) (*6) Regulation MBA3300RC Specification MBA3174RC 5 to 55 °C -40 to 70 °C -40 to 70 °C MBA3073RC 5 to 60 °C 20 °C/h or less 5 to 95 %RH 5 to 95 %RH
  • Fujitsu MBA3147RC | Product Manual - Page 28
    Environmental/Power requirements (2/2) Item Power requirement Ripple (+5V, +12V) (*5) MBA3300RC Specification MBA3174RC MBA3073RC 250mVp-p or less (*7) (*1) For detail condition, see Section 4.1. (*2) Vibration applied to the HDD is measured at near the mounting screw hole on the frame as much
  • Fujitsu MBA3147RC | Product Manual - Page 29
    conditions, power trouble, host system trouble, cable failures, or other failures not caused by the equipment are not considered. (2) Mean Time To Repair (MTTR) MTTR is the average time taken by a well-trained service mechanic to diagnose and repair an HDD malfunction. The HDD is designed for
  • Fujitsu MBA3147RC | Product Manual - Page 30
    Specifications (4) Data security at power failure Integrity of the data on the disk is guaranteed against all forms of DC power failure except on blocks where a write operation is being performed. The above does not applied to formatting disks or assigning alternate blocks. 26 C141-E252
  • Fujitsu MBA3147RC | Product Manual - Page 31
    is accessed inside the HDDs at power-on or during the execution of a specific command, but the user cannot directly access the system space. 3.1.1 Cylinder configuration The HDDs allocate cylinders to the the user's assignment (MODE SELECT command). See Subsection 3.1.2 for details. C141-E252 27
  • Fujitsu MBA3147RC | Product Manual - Page 32
    placed at the end of the track because of a track skew or a cylinder skew. (Details are explained in Subsection 3.1.3) Figure 3.1 Cylinder configuration Apart from the above logical configuration, the HDDs intend to increase the storage capacity by dividing all cylinders into several zones and
  • Fujitsu MBA3147RC | Product Manual - Page 33
    be used for alternate blocks. See Subsections 3.1.2 and 3.3.2 for details. (2) Internal test space The internal test space is an area space The system space is an area for exclusive use of the HDDs themselves and the following information are recorded. • Defect list (P list SA space. C141-E252 29
  • Fujitsu MBA3147RC | Product Manual - Page 34
    located at the end physically because of track skew or cylinder skew. (Details are explained on Subsection 3.1.3.) Size can be specified by the MODE This number cannot be changed by users. Cell SPR299 SPR300 300 Note: This HDD manages alternate spare areas for each cell, which is a set of cylinders.
  • Fujitsu MBA3147RC | Product Manual - Page 35
    the track in formats with most logical data block lengths. The interval of the sector pulse (length of the physical sector) is decided by the HDDs internal free running clock frequency. This clock is not equal to the interval of the byte clock for each zone. Therefore, the physical sector length
  • Fujitsu MBA3147RC | Product Manual - Page 36
    varies depending on the logical data block length because the track skew and the head skew are managed for individual sectors. The HDDs automatically determine appropriate values for the track skew factor and the head skew factor according to the specified logical data block length. 3.1.4 Sector
  • Fujitsu MBA3147RC | Product Manual - Page 37
    . Single burst errors with lengths of up to 32 bits for each logical block can be detected. (6) ECC This is the 400 bits code that allows detection and correction of errors in the data field, which is capable of correcting the single burst error up to 200 bits max. on the fly
  • Fujitsu MBA3147RC | Product Manual - Page 38
    SENSE, or MODE SENSE EXTENDED command after initializing the disk. Table 3.1 Format capacity Model MBA3300RC MBA3147RC MBA3073RC Data block length 512 User blocks 585, 937 Addressing The HDDs relate a logical data block address to each physical sector at formatting. Data on the disk is accessed
  • Fujitsu MBA3147RC | Product Manual - Page 39
    blocks in the user space starting with 0 to the first data block. The HDDs treat sector 0, track 0, cylinder 0 as the first logical data block. The treatment and the logical data block allocation method in case of defective sectors exist on the disk. (2) Alternate area Alternate areas in the user
  • Fujitsu MBA3147RC | Product Manual - Page 40
    by the initiator at the initialization of the disk. This information is recorded in the system space of the HDD as the G list. To execute the alternate Auto alternate block allocation processing" of the SAS INTERFACE MANUAL for details of specifications on these commands. The logical data block
  • Fujitsu MBA3147RC | Product Manual - Page 41
    , alternate block allocation is conducted in following cases: 1) Unrecovered write offtrack condition during a media write 2) Uncorrectable Data Error during a media read (certification) *1 If above errors are detected during FORMAT UNIT command, the HDDs allocate the alternate block(s) to the
  • Fujitsu MBA3147RC | Product Manual - Page 42
    DCRT flag is cleared (DCRT flag=0) in FORMAT UNIT command. The HDDs check all initialized logical data blocks by reading them out after the above alternate block allocation is made to initialize (format) the disk. (2) Alternate block allocation by REASSIGN BLOCKS command When the REASSIGN BLOCKS
  • Fujitsu MBA3147RC | Product Manual - Page 43
    HDDs automatically execute the alternate block allocation and data duplication on the defective data block detected AWRE processing The following processings are performed when the LBA matches the one list, another alternate block is allocated.) c) SA and defect map update processing (on alternate
  • Fujitsu MBA3147RC | Product Manual - Page 44
    through the setting terminal, the auto alternate block allocation processing specification is disabled. Automatic alternate block allocation is made up to the twice error by issuing the same command again. When an error is detected in a data block in the data area, recovery data is rewritten and
  • Fujitsu MBA3147RC | Product Manual - Page 45
    4.2 Power Supply Requirements 4.3 Connection Requirements This chapter describes the environmental, mounting, power supply, and connection requirements. 4.1 Mounting Requirements 4.1.1 Dimensions Figures 4.1 show the dimensions of the HDDs and the location of the mounting screw holes. C141-E252 41
  • Fujitsu MBA3147RC | Product Manual - Page 46
    Installation Requirements (*) is a dimention between the screw holes for the bottom mouting. Figure 4.1 Dimensions [Unit: mm] 42 C141-E252
  • Fujitsu MBA3147RC | Product Manual - Page 47
    4.1 Mounting Requirements 4.1.2 Mounting orientations As shown in Figure 4.2, the HDD can be installed flat on any of its six sides. Inclination from a vertical or horizontal plane should not exceed 5°. (a) Horizontal -1 (b) Horizontal -2 (c) Vertical -1 (d) Vertical -2 (e) Upright mounting -1
  • Fujitsu MBA3147RC | Product Manual - Page 48
    be 4.5 mm ±0.8 mm. c) Tightening torque of screw must be secured with 0.59 N·m (6 kgf·cm) ±12%. d) Impact caused by the electric screwdriver must be within the HDD specifications. e) Must be handled on an anti-static mat. Figure 4.3 Mounting frame structure example 44 C141-E252
  • Fujitsu MBA3147RC | Product Manual - Page 49
    4.1 Mounting Requirements (3) Limitation of side-mounting Mount the HDDs using the 4 screw holes at the both ends on the both sides as shown in Figure 4.4. Do not use the center hole by itself. In case of using the center hole, it must be used in combination with 2 holes on both ends. (Total 6
  • Fujitsu MBA3147RC | Product Manual - Page 50
    30 mm from the HDD. At designing the system effect by measuring the surface temperature of specific ICs and the DE. These measurement or below to meet the condition for assuring an MTBF of 1,400,000 hours. An air flow of 2 Read channel LSI 3 VCM/SPM Driver 4 HDC 5 MPU Maximum temperature 60
  • Fujitsu MBA3147RC | Product Manual - Page 51
    to avoid the influence of the external magnetic field. (7) Leak magnetic flux The HDDs use a high performance magnet to achieve a high speed seek. Therefore, a leak magnetic flux at surface of the HDDs are large. Mount the HDDs so that the leak magnetic flux does not affect to near equipment. C141
  • Fujitsu MBA3147RC | Product Manual - Page 52
    Power Supply Requirements (1) Allowable input voltage and current The power supply input voltage measured at the power supply connector pin of the HDDs (receiving end) must satisfy the requirement given in Subsection 2.1.3. (For other requirements, see Items (4) and (5) below.) (2) Current waveform
  • Fujitsu MBA3147RC | Product Manual - Page 53
    line when the spindle motor rotation starts. Therefore, if more than one HDD is used, the spindle motors should be started sequentially using one of of the NOTIFY (ENABLE SPINUP) primitive so that the spindle motors of individual HDD are started in intervals of 12 seconds or more. b) Turn on the +
  • Fujitsu MBA3147RC | Product Manual - Page 54
    . The specification of this noise filter is as follows: • Attenuation: 40 dB or more at 10 MHz • Circuit construction: T-configuration as shown in Figure 4.8 is recommended. Figure 4.8 AC noise filter 4.3 Connection Requirements 4.3.1 Connector location Figure 4.9 shows a location of the interface
  • Fujitsu MBA3147RC | Product Manual - Page 55
    4.3 Connection Requirements 4.3.2 Interface connector Figure 4.10 shows the SAS type interface connector (SAS plug) overview. Table 4.2 lists the signal allocation of the SAS plug on the HDDs. Top view Bottom view Top view Bottom view Figure 4.10 SAS plug connector overview C141-E252 51
  • Fujitsu MBA3147RC | Product Manual - Page 56
    Table 4.2 Interface connector (SAS plug) signal allocation:CN1 Pin No. Signal Description S1 GND GND for SAS Primary Port S2 RP+ SAS Primary Port Receive (positive) signal S3 RP- SAS Primary Port Receive (negative) signal S4 GND GND for SAS Primary Port S5 TP- SAS Primary Port
  • Fujitsu MBA3147RC | Product Manual - Page 57
    resistance is 220 Ω. For +5 V Vcc voltage, recommended resistance is 330 Ω. 4.3.4 Connector requirements Table 4.3 lists the recommended connectors for the host system. Table 4.3 Recommended connectors Manufacture Tyco Electronics AMP Part number 1735104-1 1735105-1 1735164-1 1735234-1 Remarks
  • Fujitsu MBA3147RC | Product Manual - Page 58
    This page is intentionally left blank.
  • Fujitsu MBA3147RC | Product Manual - Page 59
    This chapter describes the notes on handling HDDs, setting, mounting HDDs, confirming HDD operations after installation and preparation for use, and dismounting HDDs. 5.1 Notes on Handling HDDs The items listed in the specifications in Table 2.3 must be strictly observed. (1) General notes a) Do
  • Fujitsu MBA3147RC | Product Manual - Page 60
    cushions and packages as those at delivery. (For details, see Section 6.5.) If those at delivery cannot be used, use a package with shock absorption so that the HDD is free from direct shocks. In this case, fully protect the PCBA and interface connector so that they are not damaged. (5) Delivery
  • Fujitsu MBA3147RC | Product Manual - Page 61
    specific to each system. The general mounting method and items to be checked are shown below. See Section 4.1 for the details of requirements for installing the HDDs. 1) With a system to which an external operator panel is mounted, if it is difficult to access the connector after the HDD
  • Fujitsu MBA3147RC | Product Manual - Page 62
    a) Confirm that the transfer rate and HDD SAS addresses can be recognized during the LINK RESET sequence. b) Issue the INQUIRY, WRITE BUFFER, and READ BUFFER commands to verify that data is received and transmitted normally in the interface. (3) Verifying HDD operation : When the LINK RESET sequence
  • Fujitsu MBA3147RC | Product Manual - Page 63
    SAS INTERFACE MANUAL for further details. 5.4.2 Formatting Since the HDD is formatted with a specific (default) data format for each model (part number) when shipped from the factory, the disk 0 in "number of data blocks" field. In this case, the currently set value is used. b. Format parameter (
  • Fujitsu MBA3147RC | Product Manual - Page 64
    disk using the P lists, verifies data blocks after initialization, and allocates an alternate block for a defect block detected blocks. Only the position information of defect blocks detected with verification is registered in the G list. The specifications are as follows: a. Specifying CDB Specify 0
  • Fujitsu MBA3147RC | Product Manual - Page 65
    the best performance, set the parameters in consideration of the system requirements specific to the user. This section outlines the parameter setting procedures. Refer to Subsection 4.1.4 "MODE SELECT (15)", 4.1.5 "MODE SELECT EXTENDED (55)" of the SAS INTERFACE MANUAL for further details of the
  • Fujitsu MBA3147RC | Product Manual - Page 66
    Installation (1) Error recovery parameters The following parameters are used to control operations such as HDD internal error recovery: a. Read/write error recovery parameters (page code = 1) • AWRE: • ARRE: • TB: • EER: • PER: • DCR: Parameter Automatic alternate block allocation at Write
  • Fujitsu MBA3147RC | Product Manual - Page 67
    HDD Read-Ahead caching operations under the system environments. Refer to Chapter 3 "Data Buffer Management" of the SAS INTERFACE MANUAL for further details • NUMBER OF CACHE SEGMENTS Default value 0 (HDD-specific control (page cache)) 0 (enabled) 1 the system accesses the disk. When the access
  • Fujitsu MBA3147RC | Product Manual - Page 68
    spindle motor to stop completely. 2) Then, dismount the HDD using the drive mounting/dismounting mechanism, etc. of the system. When removing the HDD, avoid exposing it to shock or vibration. Just in case, stop dismounting once when SAS connector breaks off contact and wait until the spindle motor
  • Fujitsu MBA3147RC | Product Manual - Page 69
    Troubleshooting 6.5 Packaging This chapter describes diagnostics and maintenance. 6.1 Diagnostics 6.1.1 Self-diagnostics The HDDs have contents of the tests performed with the self-diagnostics. For a general check of the HDDs including the operations of the host system and interface, use a test
  • Fujitsu MBA3147RC | Product Manual - Page 70
    0.4-second intervals). The HDDs in this state post the CHECK CONDITION status to all I/O operation requests except the REQUEST SENSE command. The initiator can collect sense data when the CHECK CONDITION status is posted. Sense data contains detailed information on the error detected by the initial
  • Fujitsu MBA3147RC | Product Manual - Page 71
    , when the recoverable error is detected during the seek or the write/read test, the HDDs perform the error recovery according to the status is posted, sense data contains detailed information on the error detected by the initial self-diagnostics. The HDD status after the CHECK CONDITION status
  • Fujitsu MBA3147RC | Product Manual - Page 72
    self-diagnostics again (see item (1)). Refer to Subsection 4.4.1 "SEND DIAGNOSTIC (1D)" of the SAS INTERFACE MANUAL for further details of the command specifications. 6.1.2 Test programs The basic operations of the HDDs themselves can be checked with the self-diagnostic function. However, to check
  • Fujitsu MBA3147RC | Product Manual - Page 73
    Save data stored on the HDD to other media before requesting repair. Fujitsu does not assume responsibility if data is corrupted during servicing or repair. 6.2.1 Precautions Take the following precautions to prevent injury during maintenance and troubleshooting: High temperature To prevent injury
  • Fujitsu MBA3147RC | Product Manual - Page 74
    in the field. (4) Service system and repairs Fujitsu has the service system and repair facility for the HDD. Contact Fujitsu representative to submit information for replacing or repairing the HDD. Generally, the following information must be included: a) Model part number (P/N), revision number
  • Fujitsu MBA3147RC | Product Manual - Page 75
    can only be done by Fujitsu. • Replacement includes maintenance training and OEM engineer support. OEM engineers usually support retail dealers and distributors. • Replacement uses factory tools and test equipment. 6.2.4 Tools and test equipment HDD troubleshooting and repair in the field
  • Fujitsu MBA3147RC | Product Manual - Page 76
    Diagnostics and Maintenance 6.2.5 Tests This HDD can be tested in the following ways: • Initial seek operation check (See 6.2) Host system No Analyze system-related normal? error Yes Replaced or repair HDD HDD No normal? Yes Execute diagnostic test using a host computer or test equipment
  • Fujitsu MBA3147RC | Product Manual - Page 77
    error occurred. Then, start troubleshooting the whole host system by replacing the HDD. 6.3.3 Diagnostic test The diagnostic test is executed to find a faulty subassembly in a faulty HDD, or to check HDD performance. This test is usually a combination of specific HDD functions or group of functions
  • Fujitsu MBA3147RC | Product Manual - Page 78
    in DE or burning of the PCBA), troubleshooting is straightforward. 6.4.2 Troubleshooting with HDD replacement in the field At this level of maintenance, we recommend replacing the HDD as a unit. If replacing the HDD rectifies the fault, return the removed HDD to Fujitsu, for test and repair. If the
  • Fujitsu MBA3147RC | Product Manual - Page 79
    system cables are connected correctly. When possible, execute the system level diagnostic routine as explained in the host computer manual. This gives a detailed report of a possible fault. Check the AC voltage from the power supply. Check the DC voltage level at the power connector for the HDD. If
  • Fujitsu MBA3147RC | Product Manual - Page 80
    is normal but the test method is incorrect. To check performance, change the HDD conditions by changing the voltage or temperature. If the HDD error recurs or a possibly faulty part is found by troubleshooting, return the complete HDD to Fujitsu for repair. A media defect list must be included with
  • Fujitsu MBA3147RC | Product Manual - Page 81
    does not cover troubleshooting at the factory level. 6.4.5 Finding possibly faulty parts Finding possibly faulty parts in the field was explained in Subsection 6.4.2. This manual does not cover finding possibly faulty parts at the factory level. 6.5 Packaging When the HDD is returned to Fujitsu, the
  • Fujitsu MBA3147RC | Product Manual - Page 82
    Diagnostics and Maintenance (3) Put the above unitary packaging (packed in FCELL) into the conductivity bag by securing the cushion. (4) Put the drive with conductivity bag into the cardboard box. (5) Put the desiccant (10g) into the conductivity bag. (6) Seal the conductivity bag with the packaging
  • Fujitsu MBA3147RC | Product Manual - Page 83
    • At this time, FCELL is put in the cushion (lower) so that the FCELL opening may become downward. The I/F connector may become upward. • For less than 20 HDDs, insert the HDDs starting from the slot with the smallest number in Figure 6.4. Then place the empty FCELL in the empty slot. (3) Hold the
  • Fujitsu MBA3147RC | Product Manual - Page 84
    This page is intentionally left blank.
  • Fujitsu MBA3147RC | Product Manual - Page 85
    in detail how sense data collected from an HDD is used for troubleshooting. Sense data reflects an error in the HDD, and helps with troubleshooting. 7.1 Sense Data Collection 7.1.1 Sense data When HDDs post a CHECK CONDITION status, the current command or queued command is cleared. In such a case
  • Fujitsu MBA3147RC | Product Manual - Page 86
    Additional sense code Additional sense code qualifier 14 X'00' 15 SKSV 16 Sense key-specific information 17 18 0 0 0 Port 0 0 0 19 Additional 20 information CDB operation code Detail information 47 0 [LSB] [LSB] 0 ILI: Incorrect Length Indicator MSB: Most Significant Byte LSB
  • Fujitsu MBA3147RC | Product Manual - Page 87
    details of the following sense data, refer to Chapter 6 "Sense Data Error Recovery Methods" of the SAS INTERFACE MANUAL. Subsection 7.2.2 onwards explain troubleshooting self-diagnosis. C4 xx An HDD error occurred. 1x xx A disk read error occurred. 1x xx A disk read error occurred. 1D 00
  • Fujitsu MBA3147RC | Product Manual - Page 88
    is disk damage that was not recorded in the media defect list. In this case, assign an alternate block to the error-detected block using a REASSIGN BLOCKS command. For an explanation of the REASSIGN BLOCKS command, refer to Subsection 4.3.2 "REASSIGN BLOCKS (07)" of the SAS INTERFACE MANUAL. If
  • Fujitsu MBA3147RC | Product Manual - Page 89
    Initiator This is an SAS device which initiates input and output operations on the SAS bus. SAS Device The general name given to a device which is connected to the SAS bus (input/output device, I/O controller, host adapter, expander, etc.). SCSI Small Computer System Interface The standardized input
  • Fujitsu MBA3147RC | Product Manual - Page 90
    This page is intentionally left blank.
  • Fujitsu MBA3147RC | Product Manual - Page 91
    Gbps G list G Gigabits per second Grown defect list HDC HDD ID I/O H Hard Disk Controller Hard Disk Drive I IDentifier Input/Output L LED Light Emitting Diode LSI Large-Scale Integration circuit M MEEPRML MPU MR MTBF MTTR Modified Enhanced Extended Partial Response Maximum Likelihood
  • Fujitsu MBA3147RC | Product Manual - Page 92
    Acronyms and Abbreviations S/N SAS SCSI SCT SelfTest SP SPM S Serial/Number Serial Attached SCSI Small Computer System Interface SeCTor Self Test Save Page SPindle Motor TB TPI UnitOfl T Transfer Block Tracks Per Inch U Unit Offline VCM V Voice Coil Motor WCE W Write Cache Enable
  • Fujitsu MBA3147RC | Product Manual - Page 93
    HDD for use 58 command queuing feature 15 connection requirement 50 connector location 50 connector dimension 41 disk 17 dismounting HDDs 64 dual SAS port support 14 specification 20 G gap 33 general note 55 H hardware function test 66 hardware specification 19 hardware structure 17 HDD
  • Fujitsu MBA3147RC | Product Manual - Page 94
    41 interface connector 51 interface test downloading 16 MODE SELECT/MODE SELECT EXTENDED command 59 model name 19 mounting frame structure 44 mounting HDDs 57 mounting orientations 43 mounting procedure 57 mounting requirement 41 mounting screw 44 MTBF 24 MTTR 25 multi-segment data buffer
  • Fujitsu MBA3147RC | Product Manual - Page 95
    31 troubleshooting 74 troubleshooting at repair site 76 troubleshooting with HDD replacement in field 74 troubleshooting with part replacement in factory 77 Index U unpackaging 56 user space 29 V verify error recovery parameter 62 verifying HDD operation 58 verifying interface connection
  • Fujitsu MBA3147RC | Product Manual - Page 96
    This page is intentionally left blank.
  • Fujitsu MBA3147RC | Product Manual - Page 97
    regarding this manual. Manual code C141-E252-01EN Manual name MBA3300RC, MBA3147RC, MBA3073RC HARD DISK DRIVES PRODUCT MANUAL Please mark below. We will use your comments in planning future editions. Address: Fujitsu Learning Media Limited 37-10 Nishikamata 7-chome Oota-ku Tokyo 144-0051
  • Fujitsu MBA3147RC | Product Manual - Page 98
    This page is intentionally left blank.
  • Fujitsu MBA3147RC | Product Manual - Page 99
  • Fujitsu MBA3147RC | Product Manual - Page 100
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

C141-E252-01EN
MBA3300RC
MBA3147RC
MBA3073RC
HARD DISK DRIVES
PRODUCT MANUAL