In sta lla tion SteCph8: Connecting Power ELECTRICAL WARNING • To reduce the risk of electrical shock, this equipment has a grounding type Plug that has a third (grounding) Pin. This Plug will only fit into a grounding type outlet. If the Plug does not fit into the outlet, contact a qualified electrician to install the proper outlet. Do Not change the Plug in any way. The door Opener must be properly grounded to prevent personal injury and damage to the components. • The electrical power to the door Opener Must Be removed when the Motor Cover is removed. Electrical power must remain off while making electrical connections. A Check building codes: • • If building code requires Opener be permanently wired to building, have a licensed electrician perform step B. If you are not installing permanent wiring, go to step C. B Instructions for licensed electrician - connecting power with permanent wiring (Figure 32): • Remove power from circuit. • Remove Motor Cover. • Remove and discard Power Cord. - Cut off Power Cord inside Power Head as near Strain Relief as possible. - Remove Knock-Out Plug, Strain Relief, and Power Two Cord. (Cut Ground Wire on line side of Toroid). - Dispose of Plug, Strain Relief, and Power Cord. tabs slide out • Install required entrance bushing. • Connect permanent wiring to Power Head Wires. - White supply line to Opener White Wire. - Black supply line to Opener Black Wire. - Ground to Opener Green Wire. - Replace Motor Cover. Knockout Cut Wires here NOTE • Use only Underwriters Laboratories, Inc. (U.L.) recognized wire nuts. • The Circuit Boards are light sensitive. Ensure the Motor Cover is installed before energizing the Opener. Four screws hold Motor Cover Figure 32 Connecting power with permanent wiring - Restore Power to circuit. C Connecting Power with Plug: • Plug Opener into a grounded outlet as stated in previous electrical warning. D Perform Safe-T-Beam® alignment check: • Check if Safe-T-Beam® Source Red LED is glowing continuously (OK) or blinking (problem). • If Red LED is blinking twice, adjust Sensor Brackets as needed to make Red LED glow continuously. (Refer to page 26.) For Help, call 1-800-35-GENIE or visit www.geniecompany.com 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

19
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
C
ONNECTING
P
OWER
Installation Step 8:
A
Check building codes:
If building code requires Opener be permanently wired
to building, have a
licensed electrician
perform step B°
If you are not installing permanent wiring, go to step C°
B
Instructions for licensed electrician - connecting power
with permanent wiring
(
Figure 32
):
Remove power from circuit°
Remove Motor Cover°
Remove and discard Power Cord°
Cut off Power Cord inside Power Head as near Strain
Relief as possible°
Remove Knock-Out Plug, Strain Relief, and Power
Cord° (Cut Ground Wire on line side of Toroid)°
Dispose of Plug, Strain Relief, and Power Cord°
Install required entrance bushing°
Connect permanent wiring to Power Head Wires°
White supply line to Opener White Wire°
Black supply line to Opener Black Wire°
Ground to Opener Green Wire°
Replace Motor Cover°
Restore Power to circuit°
C
Connecting Power with Plug:
Plug Opener into a grounded outlet as stated in previous
electrical warning°
D
Perform Safe-T-Beam® alignment check:
Check if Safe-T-Beam® Source Red LED is glowing
continuously (OK) or blinking (problem).
If Red LED is blinking twice, adjust Sensor Brackets as
needed to make Red LED glow continuously°
(Refer to
page 26°)
ELECTRICAL WARNING
To reduce the risk of electrical shock, this equipment has
a grounding type Plug that has a third (grounding) Pin°
This
Plug will only fit into a grounding type outlet° If the
Plug does not fit into the outlet, contact a qualified
electrician to install the proper outlet°
Do Not
change
the Plug in any way° The door Opener must be properly
grounded to prevent personal injury and damage to the
components°
The electrical power to the door Opener
Must Be
removed
when the Motor Cover is removed°
Electrical power must
remain off while making electrical connections°
NOTE
Use only Underwriters Laboratories, Inc° (U°L°)
recognized wire nuts°
The Circuit Boards are light sensitive°
Ensure the
Motor Cover is installed before energizing
the Opener°
Figure 32
Connecting power with permanent wiring
Cut
Wires
here
Knockout
Two
tabs
slide
out
Four screws hold
Motor Cover