Haier HW50-1010 User Manual - Page 15

Error Signals

Page 15 highlights

Error Signals The door lock light will flash in different combinations to signal when ther e is an error, see the table below for the meanings. Error message Error 1: The start indicator wasn't lighted,and the buzzer sound abnormaly. Error 2: The start indicator lighted on 0.2s and off 0.2s for twice,repeate 4s later . Cause Door not shut pr operly. Drainage error, water has not emptied within 4 minutes. Solution Shut door pr operly. Clean the filter (page 15) and check drain hose for blockages. If pr oblem continues, contact an appr oved service engineer. Error 3: The start indicator lighted on 0.2s and off 0.2s for 3 times,repeate 4s later . Temperature sensor is not properly connected or damaged. Contact an appr oved service engineer. Error 4: The start indicator lighted on 0.2s and off 0.2s for 4 times,repeate 4s later . Heating element error, set temperature is not reached within specifi ed time (this will be displayed at the end of the programme). Contact an appr oved service engineer. Error 5: The start indicator lighted on 0.2s and off 0.2s for 5 times,repeate 4s later . Correct water level not reached within 8 minutes. Ensure the tap is fully open and water pressure is normal. If problem continues, contact an appr oved service engineer. Error 6: The start indicator lighted on 0.2s and off 0.2s for 6 times,repeate 4s later . Timer error. Contact an appr oved service engineer. Error 7: The start indicator lighted on 0.2s and off 0.2s for 7 times,repeate 4s later . Motor overheating. Contact an appr oved service engineer. Error 8: The start indicator lighted on 0.2s and off 0.2s for 8 times,repeate 4s later . Water overflow. Contact an appr oved service engineer. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

14
Error message
Cause
Solution
1:
The start indicator wasn't lighted,and the
buzzer sound abnormaly.
Door not shut properly.
Shut door properly.
2:
The start indicator lighted on 0.2s and
off 0.2s for twice,repeate 4s later .
Drainage error, water has not emptied
within 4 minutes.
Clean the filter (page 15) and check drain
hose for blockages. If pr oblem continues,
contact an approved service engineer.
3:
The start indicator lighted on 0.2s and
off 0.2s for 3 times,repeate 4s later .
Temperature sensor is not properly
connected or damaged.
Contact an approved service engineer.
4:
The start indicator lighted on 0.2s and
off 0.2s for 4 times,repeate 4s later .
Heating element error, set temperature
is not reached within specifi ed time
(this will be displayed at the end of the
programme).
Contact an approved service engineer.
5:
The start indicator lighted on 0.2s and
off 0.2s for 5 times,repeate 4s later .
Correct water level not reached within 8
minutes.
Ensure the tap is fully open and water
pressure is normal. If problem continues,
contact an approved service engineer.
6:
The start indicator lighted on 0.2s and
off 0.2s for 6 times,repeate 4s later .
Timer error.
Contact an approved service engineer.
7:
The start indicator lighted on 0.2s and
off 0.2s for 7 times,repeate 4s later .
Motor overheating.
Contact an approved service engineer.
8:
The start indicator lighted on 0.2s and
off 0.2s for 8 times,repeate 4s later .
Water overflow.
Contact an approved service engineer.
Error Signals
The door lock light will flash in different combinations to signal when ther e is an error, see the table below
for the meanings.
Error
Error
Error
Error
Error
Error
Error
Error