Electrolytic Cell and Flow Switch: The electrolytic cell and flow switch cables are terminated with connectors which plug into the AquaRite, for easy attachment and removal. The door of the AquaRite must be open to access the cell cable connector. The flow switch plugs into a connector (similar to a telephone jack) located outside, on the bottom of the enclosure. Refer to the diagram below for the location of these connections. Optional Hayward, Pentair and Polaris controls: The Hayward, Pentair and Polaris controls use a 4 wire connection to communicate to the AquaRite and can be wired up to 500' apart. Any outdoor rated 4 conductor cable can be used. Refer to each manufacturer's instructions and the wiring diagrams below for proper wiring connection to the AquaRite. NOTE: There must be only 1 "primary" unit. All other AquaRite units must be configured as "secondary". Hayward - Attach wires to proper screw terminals as shown below. Pentair - Attach wires to opposite numbered screw terminals as shown below. Note that the colors marked on the Pentair PCB do not match the AquaRite. Polaris - Attach wires to proper screw terminals as shown below. Note that screw terminal "1" is marked on the Polaris PCB. 14 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Electrolytic Cell and Flow Switch:
The electrolytic cell and flow switch cables are terminated with
connectors which plug into the AquaRite, for easy attachment and removal.
The door of the AquaRite
must be open to access the cell cable connector.
The flow switch plugs into a connector (similar to a
telephone jack) located outside, on the bottom of the enclosure.
Refer to the diagram below for the
location of these connections.
Optional Hayward, Pentair and Polaris controls:
The Hayward, Pentair and Polaris controls use a 4 wire connection to communicate to the AquaRite
and can be wired up to 500' apart.
Any outdoor rated 4 conductor cable can be used.
Refer to
each manufacturer's instructions and the wiring diagrams below for proper wiring connection to the
AquaRite. NOTE: There must be only 1 "primary" unit.
All other AquaRite units must be configured
as "secondary".
Hayward - Attach wires to proper screw terminals as shown below.
Pentair - Attach wires to opposite numbered screw terminals as shown below.
Note that the colors
marked on the Pentair PCB do not match the AquaRite.
Polaris - Attach wires to proper screw terminals as shown below. Note that screw terminal "1" is
marked on the Polaris PCB.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS