Hayward PL-PLUS Operation Manual - Page 13

Plus 16v Super Chlorinate function. - manual

Page 13 highlights

When you have an unusually high bather load, a large amount of rain, a cloudy water condition, or any other condition that requires a large amount of chlorine to be introduced to the pool, activate the Aqua Plus 16v Super Chlorinate function. The Aqua Plus 16v will turn on the filter pump, set the pool/spa valves to the correct position, and set the chlorine generator to maximum output. The superchlorinate function will continue for the programmed number of hours (see Timers/Super Chlorinate Hours) overriding the normal filter pump timeclock settings. At the end of the super chlorinate period, the pool will return to normal operation. If you manually turn off the filter pump (using the "FILTER" button on any display/keypad), the super chlorinate function terminates. When you turn the filter pump back on, super chlorinate will resume for the balance of the programmed number of hours. Spa Chlorinator 3% Adjust the desired chlorinator output for spa (0,1,2,3...9,10,15,20...95,100%) Move to previous/next menu item This setting will appear only if the chlorinator function is enabled and system has been setup for "spa only" or "pool and spa-std". If an AQL-CHEM is being used, super chlorinate will not be available if chemical sensing is enabled and ORP is in Auto Sensing (see AQL-CHEM manual). It will determine the chlorinator output when the system is operating in spa-only mode. The actual amount of chlorine introduced into the spa is determined by: this setting, the amount of time the pool operates in spa-only mode, the water temperature, and the amount of salt in the water. If the filter pump is running due to the freeze protection feature, then the chlorinator will not operate during this time. Pool Chlorinator 60% Adjust the desired chlorinator output for pool (0,1,2,3...9,10,15,20...95,100%) Move to previous/next menu item This setting will appear only if the chlorinator function is enabled and system has been setup for "pool only" or "pool and spa". If an AQL-CHEM is being used, super chlorinate will not be available if chemical sensing is enabled and ORP is in Auto Sensing (see AQL-CHEM manual). It will determine the chlorinator output when the system is operating in pool-only or spa spillover modes. The actual amount of chlorine introduced into the pool is determined by: this setting, the amount of time the filter pump is running, the water temperature, and the amount of salt in the water. If the filter pump is running due to the freeze protection feature, then the chlorinator will not operate during this time. Pool High Speed 100% Adjust the desired high speed for variable speed operation Move to previous/next menu item This setting will appear if "spa only" is not selected and variable speed filter pump is enabled. This setting determines the speed of the pump during high speed pool or spillover operation. This value can be set from 20% to "Highest Speed" in 5% increments. "Highest Speed" is default. For PS models using dual equipment, this is the pool filter high speed. Pool Low Speed 50% Adjust the desired low speed for variable speed operation Move to previous/next menu item This setting will appear if "spa only" is not selected and variable speed filter pump is enabled. This setting determines the speed of the pump during low speed pool or spillover operation. This value can be set from "Lowest Speed" to 50% in 5% increments. 50% is default. For PS models using dual equipment, this is the pool filter low speed. if Aux1 is configured as "ColorLogic" Aux1 Settings Push to access ColorLogic settings + to view/change Move to previous/next menu item This menu will appear if an aux has been configured as "ColorLogic". Use this menu to select custom colors and lightshows for your networked ColorLogic lights. Refer to the AQL-COLOR-MODHV manual for specific information on these settings. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

10
When you have an unusually high bather load, a large amount of rain, a cloudy water condition, or any
other condition that requires a large amount of chlorine to be introduced to the pool, activate the Aqua
Plus 16v Super Chlorinate function.
The Aqua Plus 16v will turn on the filter pump, set the pool/spa
valves to the correct position, and set the chlorine generator to maximum output.
The superchlorinate
function will continue for the programmed number of hours (see Timers/Super Chlorinate Hours)
overriding the normal filter pump timeclock settings.
At the end of the super chlorinate period, the pool
will return to normal operation.
If you manually turn off the filter pump (using the “FILTER” button on any display/keypad), the super
chlorinate function terminates.
When you turn the filter pump back on, super chlorinate will resume for
the balance of the programmed number of hours.
Spa Chlorinator
3%
Adjust the desired chlorinator output for spa (0,1,2,3...9,10,15,20...95,100%)
Move to previous/next menu item
This setting will appear only if the chlorinator function is enabled and system has been setup for “spa
only” or “pool and spa-std”.
If an AQL-CHEM is being used, super chlorinate will not be available if
chemical sensing is enabled
and ORP is in Auto Sensing (see AQL-CHEM manual).
It will determine
the chlorinator output when the system is operating in spa-only mode.
The actual amount of chlorine
introduced into the spa is determined by: this setting, the amount of time the pool operates in spa-only
mode, the water temperature, and the amount of salt in the water.
If the filter pump is running due to the
freeze protection feature, then the chlorinator will not operate during this time.
Pool Chlorinator
60%
Adjust the desired chlorinator output for pool (0,1,2,3...9,10,15,20...95,100%)
Move to previous/next menu item
This setting will appear only if the chlorinator function is enabled and system has been setup for “pool
only” or “pool and spa”.
If an AQL-CHEM is being used, super chlorinate will not be available if
chemical sensing is enabled
and ORP is in Auto Sensing (see AQL-CHEM manual).
It will determine
the chlorinator output when the system is operating in pool-only or spa spillover modes.
The actual
amount of chlorine introduced into the pool is determined by:
this setting, the amount of time the filter
pump is running, the water temperature, and the amount of salt in the water.
If the filter pump is running
due to the freeze protection feature, then the chlorinator will not operate during this time.
Pool High Speed
100%
Adjust the desired high speed for variable speed operation
Move to previous/next menu item
This setting will appear if “spa only” is
not selected and variable speed filter pump is enabled.
This
setting determines the speed of the pump during high speed pool or spillover operation.
This value
can be set from 20% to “Highest Speed” in 5% increments. “Highest Speed” is default.
For PS models using dual equipment, this is the pool filter high speed.
Pool Low Speed
50%
Adjust the desired low speed for variable speed operation
Move to previous/next menu item
This setting will appear if “spa only” is
not selected and variable speed filter pump is enabled.
This
setting determines the speed of the pump during low speed pool or spillover operation.
This value can
be set from “Lowest Speed” to 50% in 5% increments. 50% is default.
For PS models using dual equipment, this is the pool filter low speed.
Aux1 Settings
+ to view/change
Move to previous/next menu item
Push to access ColorLogic settings
if Aux1 is configured as "ColorLogic"
This menu will appear if an aux has been configured as “ColorLogic”.
Use this menu to select custom
colors and lightshows for your networked ColorLogic lights.
Refer to the AQL-COLOR-MODHV
manual for specific information on these settings.