Removal Instructions "EASY OPENING BOTTOM" 6. "EASY OPENING BOTTOM". The purpose of the "EASY OPENING BOTTOM" is to allow quick access to the turbine/vacuum chamber for easy cleaning and maintenance. Should the Pool Vac Ultra stop moving or become sluggish due to debris trapped in the throat or inside the unit, the turbine/vacuum chamber is accessible following the instructions on pages 12 and 13 of this manual. 1. Turn off pump. 2. Remove Pool Vac Ultra from pool. 3. Disconnect Pool Vac Ultra from leader hose. 4. Turn Pool Vac Ultra upside down. 5. Locate and loosen the captive screw behind the throat in the center of the bottom (see Figures 14 and 15). 6. Lift "Easy Opening Bottom" (see Figures 14 and 15). 7. Clean turbine/vacuum chamber (see Figure 16). 8. Check turbine for free movement. 9. Reinstall "Easy Opening Bottom" by lining up the cover screen with the two slots shown in Figures 14 and 15. Then slide the cover in place and tighten the captive screw. 10. Reinstall Pool Vac Ultra in pool per installation instructions and/or installation video. Figure 16 TURBINE/VACUUM CHAMBER 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Removal Instructions
14
“EASY OPENING BOTTOM”
6. “EASY OPENING BOTTOM”.
The purpose of the “EASY OPENING BOTTOM” is to allow quick access to the turbine/vacuum chamber for easy
cleaning and maintenance.
Should the Pool Vac Ultra stop moving or become sluggish due to debris trapped in the throat or inside the unit,
the turbine/vacuum chamber is accessible following the instructions on pages 12 and 13 of this manual.
1. Turn off pump.
2. Remove Pool Vac Ultra from pool.
3. Disconnect Pool Vac Ultra from leader hose.
4. Turn Pool Vac Ultra upside down.
5. Locate and loosen the captive screw behind the throat in the center of the bottom
(see Figures 14 and 15)
.
6. Lift “Easy Opening Bottom”
(see Figures 14 and 15)
.
7. Clean turbine/vacuum chamber
(see Figure 16)
.
8. Check turbine for free movement.
9. Reinstall “Easy Opening Bottom” by lining up the cover screen with the two slots shown in Figures 14
and 15. Then slide the cover in place and tighten the captive screw.
10. Reinstall Pool Vac Ultra in pool per installation instructions and/or installation video.
Figure 16
TURBINE/VACUUM CHAMBER