Hayward Pool Vac XL All Models - Page 6

Step 6 - won t turn

Page 6 highlights

Installation INSTALLING YOUR POOL VAC ULTRA IS SIMPLE... Step 6 Check the water flow reading on the Flow Gauge. (Refer to Step 4, Figure 2). The black disk should be in the box between the "MIN" and "MAX" markings. If the setting is higher than required with the black disk outside of the box on the "MAX" side and you have connected your hose to the skimmer, it will be necessary to reduce the vacuum/water flow by using a valve or valves in the filter system, or the Hayward V094 Regulator Valve or an optional Hayward Automatic Skimmer Vacuum Plate designed to adjust vacuum/water flow. To install the V094 Regulator Valve, turn the filter system off. Remove the hose from the V093C Skimmer Cone, and after closing the Regulator Valve (Rotate the blue collar clockwise/toward + until closed/tight), insert the Regulator Valve into the Skimmer Cone, and insert the hose end into the Regulator Valve (see Figure 4). Turn the filter system on and allow it to run long enough to eliminate any air in the system. Turn the blue collar counter clockwise until the proper reading appears on the gauge. If a Hayward Skimmer Vacuum Plate is to be used, follow the installation instructions included with the Skimmer Vacuum Plate. VO94 REGULATOR VALVE VO93C CONE ADAPTER TO TO MAIN DRAIN PUMP (if applicable) Figure 4 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Installation
INSTALLING YOUR POOL VAC ULTRA IS SIMPLE...
4
Step 6
Check the water flow reading on the Flow Gauge. (Refer to Step 4, Figure 2). The black disk should be in the box
between the “MIN” and “MAX” markings. If the setting is higher than required with the black disk outside of the
box on the “MAX” side and you have connected your hose to the skimmer, it will be necessary to reduce the
vacuum/water flow by using a valve or valves in the filter system, or the Hayward V094 Regulator Valve or an
optional Hayward Automatic Skimmer Vacuum Plate designed to adjust vacuum/water flow. To install the V094
Regulator Valve, turn the filter system off. Remove the hose from the V093C Skimmer Cone, and after closing the
Regulator Valve (Rotate the blue collar clockwise/toward + until closed/tight), insert the Regulator Valve into the
Skimmer Cone, and insert the hose end into the Regulator Valve (see Figure 4).
Turn the filter system on and allow it to run long enough to eliminate any air in the system.Turn the blue collar
counter clockwise until the proper reading appears on the gauge.
If a Hayward Skimmer Vacuum Plate is to be used, follow the installation instructions included with the Skimmer
Vacuum Plate.
Figure 4
VO94
REGULATOR
VALVE
VO93C
CONE
ADAPTER
TO MAIN DRAIN
(if applicable)
TO
PUMP