Hayward Pro Logic Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation - Page 18
Group Function, Maintenance Menu - pool lights
View all Hayward Pro Logic manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
you manually turn on the Aux1 relay until the Pro Logic automatically turns off the relay. You can also manually turn off the relay at an earlier time by pressing the AUX1 button. NOTE: The configurations for Valve3 and Valve4 are identical. However, if Heater2 was enabled, then the Valve4 configura- tion will not appear (a single relay is used to implement either the Heater2 function or the Valve4 function--it can not do both). Set VDaalvyea3n-dallTime W8e:d3n0eAsdtaoy 41:00:03P7P or Valve3-wkend Adjust time setting Move between start and stop times & to previous/next menu item Adjust time setting 8:30A to 4:00P Move between start and stop times & to previous/next menu item Valve3-wkday 8:30A to 4:00P Adjust time setting Move between start and stop times & to previous/next menu item or This menu will appear only if Valve3 is configured for timeclock. The valve will rotate on and off at the designated times. SVeatlvDe3ay-CaonudnTtDimne Wednes0d:a2y010:37P Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15...) Move to previous/next menu item This menu will appear only if the valve3 is configured for countdown timer. This setting is the time after you manually turn on the valve3 relay until the Pro Logic automatically turns off the relay. You can also manually turn off the valve at an earlier time by pressing the VALVE3 button. Super Chlorinate 24 hours Adjust Superchlorination period (1 - 96 hours) Move to previous/next menu item For larger pools or when you have an unusually high bather load, a large amount of rain, a cloudy water condition, or any other condition that requires a large amount of chlorine to be introduced to the pool, may require more hours of Superchlorination. Smaller pools require less hours of Superchlorination. Group Function The Pro Logic offers the ability to assign a Group function to a particular button. Instead of a button controlling one particular function, the button can be programmed to initiate a sequence of commands that are programmed in the Configuration Menu. For example, instead of the Lights button turning on and off the pool light only, the button can be programmed to turn on the pool light, turn on the bug light, turn off the pool cleaner, turn on and dim the patio lights, turn on the music, etc. all at the same time. This convenient feature is offered on all Aux buttons, both Valve buttons and the Lights button. The Pro Logic can be programmed to control up to four groups. Refer to this section when programming Group commands. Before assigning and configuring all the desired functions and their control parameters, the group itself must be configured. The options for controlling groups are Manual On/Off, Countdown Timer, and Timeclock. The group will turn on and off based on this selection. When setting up a Group function in the Configuration Menu, the first menu allows you to select the control parameter (how the group is activated and de-activated) and the second menu allows you to select which Pro Logic functions are to be controlled in the group. 15 if ColorLogic Network Module is detected Reset ColorLogic to Initiate reset of ColorLogic configuration parameters Default Press + Move to previous/next configuration menu (config. not reset) Are you sure? + to proceed Reset all configuration parameters Move to previous/next menu (config. not reset) ColorLogic. reset Confirmed Move to previous/next configuration menu Use this function to erase all ColorLogic configuration settings and reset back to the factory default values. This function is NOT reversible--be careful. Reset Config. to Default Press + Initiate reset of all configuration parameters Move to previous/next configuration menu (config. not reset) Are you sure? + to proceed Reset all configuration parameters Move to previous/next menu (config. not reset) Config. reset Confirmed Move to previous/next configuration menu Use this function to erase all previous system configuration settings and reset all configuration parameters back to the factory default values. This function is NOT reversible--be careful. Maintenance Menu (only displays if Sensing System is enabled) The Maintenance Menu will be displayed only if the optional AQL-CHEM is used and the Sensing System is enabled in the Chemistry Config. Wizard. This menu is used to perform functions relating to the AQL-CHEM ORP and pH sensing kit. pH Calibration Wizard, + to enter Push to access pH Calibration Wizard Move to previous/next menu item Use this Wizard to calibrate the AQL-CHEM's pH probe. This requires a manual pH test of the pool water using a dependable red phenol test kit. Clean Probe Wizard + to enter Push to access Clean Probe Wizard Move to previous/next menu item Use this Wizard to clean the AQL-CHEM's ORP and pH probes. The probes must be clean and free from oil, chemical deposits and contamination to function properly. Slow response, increased need to calibrate, and inconsistent readings are indications that the probes need to be cleaned. 32