Hayward Pro Logic Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation - Page 20

Configuration Menus - operation manual

Page 20 highlights

Super Chlorinate The Pro Logic can be programmed to Super Chlorinate the pool or spa while running a group command. When the Group starts, the Super Chlorinate cycle will begin. Super Chlorinate will continue until the preset time expires (see Timers Menu/Super Chlorinate Hours) or until the Group turns off. Changing the Super Chlorinate state using the Settings Menu, the Aqua Pod Super Chlorinate button, or a Super Chlorinate assigned Aux/Lights/Valve button will temporarily cancel the Group's control of Super Chlorinate until the next time the Group is activated. Variable Speed in Groups The Pro Logic can be programmed to use alternate pump speeds while running group commands. This allows the pump(s) to be set to a higher or lower speed than normal, while the group is activated. When the group stops, the speed will return to its normal setting. Changing the speed setting while the group is running will make the group release the alternate speed setting and revert back to the normal speed setting. Any changes that are made at that point will affect the normal speed setting. The next time the group is activated, the speed will return to the group speed setting that was originally programmed in the Configuration Menu. To change the speed setting while the group is running, go to the Settings menu and press the +/- button while "Group Control" is displayed. The speed setting will change to the normal speed setting. PS-8 and PS-16 Virtual Models Pro Logic Virtual models are similar to standard PS models, but offer additional auxiliary outputs with limited functionality. The PL-PS-8-V is similar to the PL-PS-4 with 4 additional Aux outputs. The PL-PS-16-V is similar to the PL-PS-8 with 8 additional outputs. The additional aux outputs on virtual models can only be assigned to the Super Chlorinate function (if the Chlorinator is enabled) or to a Group function. Refer to the following programming information when assigning functions to the virtual auxiliary outputs. Configuration Menus Each item needs to be programmed and may contain additional sub-menu items. Refer to the following pages for information on programming. Chlor. Config. + to view/change Chlorinator Enabled Display Salt Cell Type T-CELL-15 Push to access Chlorinator option Move to next configuration menu Toggle between Chlorinator Enabled and Disabled (default) Move to next menu item Toggle between Display Salt (default) and Minerals Move to previous/next configuration menu Rotates between available Cell types Move to next menu item Chlorinator Requires the use of a chlorinator cell and P-KIT sold separately. If the chlorinator is enabled, then the cell and flow switch must also be installed and the Pro Logic will automatically chlorinate both the pool and spa according to the desired output setting (see Settings Menu in the Operation manual). If disabled (default), all displays relating to the chlorinator will be suppressed. When the chlorinator is enabled, the Pro Logic will automatically detect and control any Aqua Rite(s) that is installed in the system. Display Allows for the display of salt (default) or mineral values. Cell Type Selection The Cell Type Menu appears after "Display Salt/Minerals" in the Chlorinator Configuration Menu. The options are T-CELL-15 (default), T-CELL-9, T-CELL-5 or T-CELL-3. Make the proper selection based on the chlorinator cell that is used in your system. Refer to the information below. "T-CELL-3" = T-CELL-3, GLX-CELL-3-W "T-CELL-5" = GLX-CELL-5, GLX-CELL-5-W "T-CELL-9" = T-CELL-9, GLX-CELL-9-W "T-CELL-15" = T-CELL-15, GLX-CELL-15-W 17 function is terminated. See valve3 Group section for operation information for the Group function. Super Chlorinate - The Super Chlorinate function can be assigned to any Aux, Lights or Valve button. This allows the user to simply hit a button to start a Super Chlorinate cycle, rather than using the Settings Menu. Note that only one button can me assigned to this function. Valve3 Interlock If "Enabled", this feature will override the function (timeclock, manual on/off, countdown timer or infloor cleaner) selected above and turn the valve off whenever the filter pump is off or the pool/spa suction/return valves are set to "spa only" or "spillover" operation. Interlock is not available with solar, group or super chlorinate. Valve3 Group The valve3 Group function allows the user to perform multiple tasks with a single push of the VALVE3 button. When setting up a Group function, refer to page 15 for specific programming information. There are two Group menus; the first menu determines how the group command will be initiated (Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions and their respective control parameters. When activating Group functions, be aware that the most recent Group function that is initiated will override any previous Group function. Valve3 External Input Interlock When Valve3 External Input Interlock is enabled, the Valve3 output will be forced off when the external input is active. This will have precedence over freeze protection. Valve3 External Input Interlock is not available for solar, group, and super chlorinate. Valve3 Freeze Protection This function protects the pool and plumbed equipment against freeze damage. If Freeze Protection is enabled and the AIR temperature falls sensor falls below the selected freeze protection temperature, the Pro Logic will turn on the valve to allow circulation of the water. IMPORTANT: this only enables operation of the valve3 output during freeze--see the "Filter Pump Config." menu to enable freeze protection for the main circulation system. Freeze protection is not available for group or super chlorinate functions. Valve3 Pump Speed This is the speed of the pump when the Valve3 output is on. The default selection is "Settings Menu". This is the speed of the pump that has been selected in the Settings Menu for normal filter operation. If an alternate speed is desired when the Valve3 output is on, push "+" or "-" and select from "Filter Lowest" to "Filter Highest" in 5% increments. if AQL-SS-6B is connected 6B Spa Config. + to view/change Select 6B Spa A 6B A, Button 1 Pool/Spa Push to access the 6 Button Spa Side Remote options Move to previous/next configuration menu Rotates between all available remotes Move to next menu item Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3, Valve4, and all available Aux outputs Move to previous/next menu item or next configuration menu Select 6B Spa This menu only appears if more than one AQL-SS-6B is detected at power up. Select which of the available remote controls (A, B or C) is to be configured. 6B A, Button 1 This menu allows the user to map each button of the AQL-SS-6B to one of the standard Pro Logic functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3 - Lights, Button 4 - Heater1, Button 5 - Aux1 and Button 6 - Aux2. 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

17
Super Chlorinate
The Pro Logic can be programmed to Super Chlorinate the pool or spa while running a group command. When the
Group starts, the Super Chlorinate cycle will begin.
Super Chlorinate will continue until the preset time expires (see
Timers Menu/Super Chlorinate Hours) or until the Group turns off.
Changing the Super Chlorinate state using the
Settings Menu, the Aqua Pod Super Chlorinate button, or a Super Chlorinate assigned Aux/Lights/Valve button
will temporarily cancel the Group’s control of Super Chlorinate until the next time the Group is activated.
Variable Speed in Groups
The Pro Logic can be programmed to use alternate pump speeds while running group commands. This allows the
pump(s) to be set to a higher or lower speed than normal, while the group is activated. When the group stops, the
speed will return to its normal setting.
Changing the speed setting while the group is running will make the group release the alternate speed setting and
revert back to the normal speed setting. Any changes that are made at that point will affect the normal speed
setting.
The next time the group is activated, the speed will return to the group speed setting that was originally
programmed in the Configuration Menu. To change the speed setting while the group is running, go to the Settings
menu and press the +/- button while “Group Control” is displayed.
The speed setting will change to the normal
speed setting.
PS-8 and PS-16 Virtual Models
Pro Logic Virtual models are similar to standard PS models, but offer additional auxiliary outputs with limited
functionality.
The PL-PS-8-V is similar to the PL-PS-4 with 4 additional Aux outputs.
The PL-PS-16-V is similar
to the PL-PS-8 with 8 additional outputs. The additional aux outputs on virtual models can only be assigned to the
Super Chlorinate function (if the Chlorinator is enabled) or to a Group function.
Refer to the following program-
ming information when assigning functions to the virtual auxiliary outputs.
Configuration Menus
Each item needs to be programmed and may contain additional sub-menu items.
Refer to the following pages for
information on programming.
Cell Type
T-CELL-15
Rotates between available Cell types
Move to next menu item
Move to next menu item
Chlorinator
Enabled
Display
Salt
Chlor. Config.
+ to view/change
Toggle between Display Salt (default) and Minerals
Toggle between Chlorinator Enabled and Disabled (default)
Move to previous/next configuration menu
Move to next configuration menu
Push to access Chlorinator option
Cell Type
T-CELL-15
Chlorinator
Enabled
Display
Salt
Chlor. Config.
+ to view/change
Chlorinator
Requires the use of a chlorinator cell and P-KIT sold separately.
If the chlorinator is enabled, then
the cell and flow switch must also be installed and the Pro Logic will automatically chlorinate both the
pool and spa according to the desired output setting (see Settings Menu in the Operation manual).
If
disabled (default), all displays relating to the chlorinator will be suppressed.
When the chlorinator is enabled, the Pro Logic will automatically detect and control any Aqua Rite(s)
that is installed in the system.
Display
Allows for the display of salt (default) or mineral values.
Cell Type Selection
The Cell Type Menu appears after “Display Salt/Minerals” in the Chlorinator Configuration Menu.
The options are T-CELL-15 (default), T-CELL-9, T-CELL-5 or T-CELL-3.
Make the proper selection
based on the chlorinator cell that is used in your system. Refer to the information below.
"T-CELL-3" = T-CELL-3, GLX-CELL-3-W
"T-CELL-5" = GLX-CELL-5, GLX-CELL-5-W
"T-CELL-9" = T-CELL-9, GLX-CELL-9-W
"T-CELL-15" = T-CELL-15, GLX-CELL-15-W
30
function is terminated.
See valve3 Group section for operation information for the Group function.
Super Chlorinate
– The Super Chlorinate function can be assigned to any Aux, Lights or Valve
button.
This allows the user to simply hit a button to start a Super Chlorinate cycle, rather than using
the Settings Menu.
Note that only one button can me assigned to this function.
Valve3 Interlock
If “Enabled”, this feature will override the function (timeclock, manual on/off, countdown timer or in-
floor cleaner) selected above and turn the valve off whenever the filter pump is off or the pool/spa
suction/return valves are set to “spa only” or “spillover” operation.
Interlock is not available with
solar, group or super chlorinate.
Valve3 Group
The valve3 Group function allows the user to perform multiple tasks with a single push of the VALVE3
button. When setting up a Group function, refer to page 15 for specific programming information.
There are two Group menus; the first menu determines how the group command will be initiated
(Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions
and their respective control parameters.
When activating Group functions, be aware that the most recent Group function that is initiated will
override any previous Group function.
Valve3 External Input Interlock
When Valve3 External Input Interlock is enabled, the Valve3 output will be forced off when the external
input is active.
This will have precedence over freeze protection. Valve3 External Input Interlock is not
available for solar, group, and super chlorinate.
Valve3 Freeze Protection
This function protects the pool and plumbed equipment against freeze damage.
If Freeze Protection
is enabled and the AIR temperature falls sensor falls below the selected freeze protection temperature,
the Pro Logic will turn on the valve to allow circulation of the water.
IMPORTANT:
this only enables
operation of the valve3 output during freeze--see the “Filter Pump Config.” menu to enable freeze
protection for the main circulation system. Freeze protection is not available for group or super
chlorinate functions.
Valve3 Pump Speed
This is the speed of the pump when the Valve3 output is on.
The default selection is “Settings Menu”.
This is the speed of the pump that has been selected in the Settings Menu for normal filter operation.
If an alternate speed is desired when the Valve3 output is on, push “+” or “-” and select from “Filter
Lowest” to “Filter Highest” in 5% increments.
6B Spa Config.
+ to view/change
6B A,
Button 1
Pool/Spa
Select 6B Spa
A
Push to access the 6 Button Spa Side Remote options
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1, Valve3,
Valve4, and all available Aux outputs
Rotates between all available remotes
Move to previous/next configuration menu
Move to previous/next menu item or next configuration menu
Move to next menu item
if AQL-SS-6B is connected
Select 6B Spa
This menu only appears if more than one AQL-SS-6B is detected at power up.
Select which of the
available remote controls (A, B or C) is to be configured.
6B A,
Button 1
This menu allows the user to map each button of the AQL-SS-6B to one of the standard Pro Logic
functions.
The default selections are:
Button 1 - Pool/Spa, Button 2 - Filter, Button 3 - Lights, Button
4 - Heater1, Button 5 - Aux1 and Button 6 - Aux2.