Hayward Pro Logic Model: PL-PS-4 PL-PS-8 PL-PS-16 PL-PS-16V Operation - Page 21

Chemistry Configuration Wizard, Pool/Spa Setup, Heaters, Spa CountDn, Spa Spillover, Valve3 Name, - relay kit

Page 21 highlights

NOTE: The configuration for Valve3 and Valve4 are identical. However, if Heater2 was enabled, then the Valve4 configuration will not appear (a single relay is used to implement either the Heater2 function or the Valve4 function--it can not do both). For PS-16, see aux logic on page 27 for control of Valves7, 8, 9 and 10. Valve3 Config. + to view/change Push to access Valve3 options Move to previous/next configuration menu Valve3 Name Waterfall Rotates between all available names Move to next menu item Valve3 Function Solar Rotates between Manual On/Off (default), Countdown Timer, Timeclock, Solar, In-floor Cleaner, Group, and Super Chlorinate Move to next menu item for all functions except solar, group or super chlorinate Valve3 Interlock Toggle between Enabled and Disabled (default) Valve3 Interlock Disabled Move to next menu item for group function only Valve3 Group Timer: None(Manual) Rotates between Manual On/Off (default),Countdown Timer and Timeclock Move to next menu item for group function only Valve3 Group Filter: Unaffected Options available depend on the function that is selected Move to previous/next menu item or next configuration menu for all functions except solar, group or super chlorinate Valve3 Ext Input Toggle between Enabled and Disabled (default) Disabled Move to previous/next configuration menu for all functions except group and super chlorinate Valve3 Freeze Toggle between Enabled and Disabled (default) Valve3 Freeze Disabled Move to previous/next configuration menu if filter pump is set to variable speed and the relay type is set to standard Valve3 Pump Spd Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest) Settings Menu Move to previous/next configuration menu Valve3 Name The Pro Logic allows you to assign any one of a number of names (e.g. "Cleaner Valve, Waterfall valve, Solar Valve, etc.) to each of the valve output control function. This will make the Pro Logic much more user friendly to the homeowner when they want to turn various valves on or off or program the timeclocks. A sheet of small name labels is included with the Pro Logic main unit and each remote display/keypad so that the "Valve3" (and "Valve4") pushbutton can be labeled the same as the name that you have assigned. Valve3 Function Manual On/Off (default) - the valve3 relay will alternate between turning on and off when the VALVE3 button is pressed. There is no automatic control logic. The VALVE3 button can also be used to turn the valve output on or off. Countdown Timer - the valve3 relay will turn on when the VALVE3 button is pressed and then will turn off automatically after a programmed time (see Timers Menu in the Operations Manual). The VALVE3 button can also be used to turn the output off. Timeclock - the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see Operations Manual). The valve3 button can also be used to turn the valve output on or off. Solar - the valve operates when the filter pump is running and solar heat is available and the water is less than the desired temperature setting. Solar heating must be enabled in the "Solar Config. menu for proper operation to occur. In-Floor Cleaner - the valve switches the water returning to the pool between the in-floor cleaner and the normal return jets which facilitate efficient surface skimming. The valve will operate the in-floor cleaner for the first half of each clock hour and then switch to the jets/skimming for the last half of the hour. Group - the valve operates when the Group function is initiated and shuts off when the Group 29 Chemistry Config. Wizard + to enter Press to access Chemistry Config. Wizard Move to previous/next menu item Chemistry Configuration Wizard Requires use of the optional AQL-CHEM Sensing Kit. Following the steps of the Chemistry Config. Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if the chlorination function is used, can configure the Pro Logic to generate the correct amount of chlorine to properly sanitize the pool. Refer to the AQL-CHEM manual for more detailed information. Pool/Spa Config. + to view/change Push to access Pool/Spa options Move to previous/next configuration menu Pool/Spa Setup Pool and Spa-Std Rotates between Pool and Spa-Std (default), Pool and Spa-Dual, Pool Only, and Spa Only options Move to next menu item if "Pool and Spa-Dual" is selected Heaters Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters Htr1=Spa,Htr2=Pool Move to next menu item if "Pool and Spa-Std" is selected Spa - CountDn Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00)) 00:30 Move to next menu item if "Pool and Spa-Std or Dual" is selected Spa Spillover Toggle between Enabled and Disabled (default) Spa Spillover Enabled Move to next menu item or previous/next configuration menu if "Pool and Spa-Std or Dual" is selected and if "Spa Spillover" is enabled Filter Operation Toggle between Pool Only (default) and Spa Spillover options Spa Spillover Move to previous/next configuration menu if "Pool Only" or "Spa Only" is selected V1=Aux1, V2=Aux2 Toggle between Enabled and Disabled (default) Disabled Move to previous/next configuration menu if "Pool and Spa-Std" is selected Filter Off Valve Toggle between Enabled (default) and Disabled Change: Enabled Move to previous/next configuration menu Pool/Spa Setup If "Pool Only" or "Spa Only" are selected, then the pool/spa valves are not needed and pushing the POOL/SPA button on the display/keypad will have no effect. If "Pool and Spa-Std" is selected, then the pool/spa suction and return valve actuators should be connected to the Pro Logic. Pressing the POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa operation. If "Pool and Spa-Dual" is selected, then only the Pool/Spa return valve actuator should be connected to the Pro Logic. Heaters This menu will only appear if Pool/Spa setup is set to "Pool and Spa-Dual". This allows the heater(s) to either be shared between the pool and spa ("Shared" selected) or for Heater1 to be dedicated to the spa and Heater2 to be dedicated to the pool ("Htr1=Spa, Htr2=Pool" selected). Spa CountDn This menu will appear only if Pool/Spa Setup is set to "Pool and Spa-Std". This setting is the time, after you manually switch the Pool/Spa valves to "Spa Only", until the Pro Logic automatically returns the valves to their previous positions. It is programmed in increments of 5 minutes, from "Manual On/Off" (0 minutes) to "21:00" (21 hours). The filter is forced on during this time period. Spa Spillover When spa spillover is "Enabled" and "Pool and Spa-Std", the homeowner will be able to rotate through "Pool Only" (both suction and return valves switched to pool), "Spa Only" (both suction and return valves switched to spa) and "Spillover" (suction valve switched to pool and return valve switched to spa) by successive presses of the "Pool/Spa" button. For "Pool and Spa-Dual", only "Pool Only" and "Spillover" are available. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

18
Chemistry Config.
Wizard + to enter
Press to access Chemistry Config. Wizard
Move to previous/next menu item
Chemistry Configuration Wizard
Requires use of the optional AQL-CHEM Sensing Kit.
Following the steps of the Chemistry Config.
Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if the chlorination function is
used, can configure the Pro Logic to generate the correct amount of chlorine to properly sanitize the
pool. Refer to the AQL-CHEM manual for more detailed information.
Pool/Spa Config.
+ to view/change
Pool/Spa Setup
Pool and Spa-Std
Spa Spillover
Enabled
Heaters
Htr1=Spa,Htr2=Pool
Filter Operation
Spa Spillover
Push to access Pool/Spa options
Rotates between Pool and Spa-Std
, Pool and Spa-Dual,
Pool Only, and Spa Only options
(default)
Toggle between Enabled and Disabled
Spa Spillover
(default)
Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters
Toggle between Pool Only
and Spa Spillover
options
(default)
Move to previous/next configuration menu
Move to next menu item
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Pool and Spa-Std or Dual” is
selected and if “Spa Spillover” is enabled
Spa - CountDn
00:30
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
Move to next menu item
if “Pool and Spa-Std” is selected
if “Pool and Spa-Dual” is selected
if “Pool and Spa-Std or Dual” is selected
V1=Aux1, V2=Aux2
Disabled
Toggle between Enabled and Disabled (default)
if “Pool Only” or “Spa Only” is selected
Move to previous/next configuration menu
Filter Off Valve
Change: Enabled
Toggle between Enabled
and Disabled
(default)
if “Pool and Spa-Std” is selected
Move to previous/next configuration menu
Pool/Spa Setup
If “Pool Only” or “Spa Only” are selected, then the pool/spa valves are not needed and pushing the
POOL/SPA button on the display/keypad will have no effect.
If “Pool and Spa-Std” is selected, then
the pool/spa suction and return valve actuators should be connected to the Pro Logic.
Pressing the
POOL/SPA button on the display/keypad will allow the homeowner to alternate between pool and spa
operation.
If “Pool and Spa-Dual” is selected, then only the Pool/Spa return valve actuator should be
connected to the Pro Logic.
Heaters
This menu will only appear if Pool/Spa setup is set to “Pool and Spa-Dual”.
This allows the heater(s)
to either be shared
between the pool and spa (“Shared” selected) or for Heater1 to be dedicated to the
spa and Heater2 to be dedicated to the pool (“Htr1=Spa, Htr2=Pool” selected).
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to “Pool and Spa-Std”.
This setting is the time,
after you manually switch the Pool/Spa valves to “Spa Only”, until the Pro Logic automatically
returns the valves to their previous positions. It is programmed in increments of 5 minutes, from
“Manual On/Off” (0 minutes) to
“21:00” (21 hours).
The filter is forced on during this time period.
Spa Spillover
When spa spillover is “Enabled” and “Pool and Spa-Std”, the homeowner will be able to rotate
through “Pool Only” (both suction and return valves switched to pool), “Spa Only” (both suction and
return valves switched to spa) and “Spillover” (suction valve switched to pool and return valve
switched to spa) by successive presses of the “Pool/Spa” button.
For “Pool and Spa-Dual”, only
“Pool Only” and “Spillover” are available.
29
NOTE: The configuration for Valve3 and Valve4 are identical.
However, if Heater2 was enabled, then the Valve4 configuration
will not appear (a single relay is used to implement either the Heater2 function or the Valve4 function--it can not do both). For
PS-16, see aux logic on page 27 for control of Valves7, 8, 9 and 10.
Valve3
Disabled
Freeze
Toggle between Enabled and Disabled (default) Valve3 Freeze
Move to previous/next configuration menu
for all functions except group and super chlorinate
Valve3 Config.
+ to view/change
Valve3 Function
Solar
Valve3 Name
Waterfall
Push to access Valve3 options
Rotates between
Manual On/Off (default), Countdown Timer,
Timeclock, Solar, In-floor Cleaner, Group, and Super Chlorinate
Move to previous/next configuration menu
Move to next menu item
Valve3
Disabled
Interlock
Toggle between Enabled and Disabled (default) Valve3 Interlock
Move to next menu item
for all functions except solar, group or super chlorinate
for all functions except solar, group or super chlorinate
Rotates between all available names
Move to next menu item
Valve3 Group
Filter: Unaffected
Valve3 Group
Timer: None(Manual)
Options available depend on the function that is selected
Rotates between Manual On/Off (default),Countdown Timer and Timeclock
Move to previous/next menu item or next configuration menu
Move to next menu item
for group function only
for group function only
Valve3 Ext Input
Disabled
Toggle between Enabled and Disabled (default)
Move to previous/next configuration menu
if filter pump is set to variable speed
and the relay type is set to standard
Valve3 Pump Spd
Settings Menu
Select Settings Menu (default) or desired pump speed (Filter Lowest to Highest)
Move to previous/next configuration menu
Valve3 Name
The Pro Logic allows you to assign any one of a number of names (e.g. “Cleaner Valve, Waterfall
valve, Solar Valve, etc.) to each of the valve output control function.
This will make the Pro Logic
much more user friendly to the homeowner when they want to turn various valves on or off or program
the timeclocks.
A sheet of small name labels is included with the Pro Logic main unit and each remote
display/keypad so that the “Valve3” (and “Valve4”) pushbutton can be labeled the same as the name
that you have assigned.
Valve3 Function
Manual On/Off (default)
– the valve3 relay will alternate between turning on and off when the
VALVE3 button is pressed.
There is no automatic control logic.
The VALVE3 button can also be used
to turn the valve output on or off.
Countdown Timer
– the valve3 relay will turn on when the VALVE3 button is pressed and then will
turn off automatically after a programmed time (see Timers Menu in the Operations Manual).
The
VALVE3 button can also be used to turn the output off.
Timeclock
– the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see
Operations Manual).
The valve3 button can also be used to turn the valve output on or off.
Solar
– the valve operates when the filter pump is running
and solar heat is available
and the water is
less than the desired temperature setting.
Solar heating must be enabled in the “Solar Config. menu
for proper operation to occur.
In-Floor Cleaner
– the valve switches the water returning to the pool between the in-floor cleaner and
the normal return jets which facilitate efficient surface skimming.
The valve will operate the in-floor
cleaner for the first half of each clock hour and then switch to the jets/skimming for the last half of the
hour.
Group
– the valve operates when the Group function is initiated and shuts off when the Group