Hayward Super Pump® VS Super Pump® VS Manual

Hayward Super Pump® VS Manual

Hayward Super Pump® VS manual content summary:

  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 1
    Super Pump® VS Owner's Manual IS2600VSP Rev C Model SP2600VSP Super Pump Variable Speed Pump The Hayward Super Pump VS is specifically engineered for the demanding requirements of today's inground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment.
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 2
    18 9.4. Seal Installation 18 9.5. Replacing the Impeller and Diffuser 18 9.6. Replacing the Motor Assembly 19 10. Replacement Parts ...19 10.1. Parts Diagram 19 11. Troubleshooting...20 Page 2 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 3
    11.1. General Problems 20 11.2. Error Codes 22 12. Warranty...22 13. Product Registration...23 Page 3 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 4
    NON-HAYWARD REPLACEMENT PARTS VOIDS WARRANTY. ATTENTION INSTALLER - THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION, OPERATION, AND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT. FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 5
    , hair decorations, fingers, toes, or knuckles to be caught in an opening of a suction outlet cover resulting in mechanical entrapment. Page 5 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 6
    prior to maintenance to minimize the risk for burns. WARNING - Failure to install according to defined instructions may result in severe personal injury or death. SAVE THESE INSTRUCTIONS Page 6 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 7
    installation and operation of the Hayward Super Pump Variable Speed Pump. The instructions in this manual MUST be followed precisely. 2.2. Primary Features Totally enclosed, permanent magnet motor Advanced hydraulic design Fully programmable with up to 3 custom speed and timer functions Motor
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 8
    pipe (to reduce friction losses).  Allow for valves in suction and discharge piping.  Be protected from excess moisture and flooding.  Allow adequate access for servicing pump and piping. Page 8 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 9
    supply available agrees with the pump's voltage, phase, and cycle, and that the wire size is adequate for the amps rating and distance from the power source. Use copper conductors only. Page 9 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 10
    going to the controller when removing. 3. Connect 230VAC line power supply wiring to the terminal block and ground screw as shown in the Input Power Wiring diagram. See section 5.1 for diagram. Page 10 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 11
    to filter to close filter manual air relief valve when a steady stream of water (not air or air and water) is discharged from valve. Failure to do so could result in severe personal injury. Page 11 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 12
    within 10 minutes, stop motor and determine cause. Be sure all suction and discharge valves are open when pump is running. See Troubleshooting Guide. 6.3. User Interface Summary Figure 6.3-1 Page 12 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 13
    are displayed. Screen Buttons Used Comments  DISP/FUNC Pump software revision number will be displayed across the screen. Displays the Motor RPM Cycles through to next screen Page 13 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 14
    Cycles through to next screen Time Display: Hours . Minutes  DISP/FUNC Display Current power usage in Watts Cycles through to next screen Note: When in prime mode the will be disabled. Page 14 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 15
    Adjust the motor rpm of V3 speed until the timer runs out for that speed or the speed is changed again. The LED for the changed speed will FLASH as long as a modified speed is running and has not been saved. Page 15 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 16
    remove power from the pump. Press and Hold DISP/FUNC and apply power to the pump. In this mode only the motor RPM's can be changed. To exit from service mode, cycle the power to the pump off and on. Page 16 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 17
    from mounting pad, wiring (after power has been turned OFF), and piping. 4. Once the pump is fully drained of water, re-install the strainer cover and drain plugs. Store pump in a dry area. Page 17 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 18
    by holding motor shaft with wrench as noted in step #3. 12. Place the diffuser over the impeller and onto the seal plate, aligning the rib on the left side with the slot on the left of the diffuser. Page 18 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 19
    Strainer Cover Gasket Basket Drain Plug With Gasket Pump/Strainer Housing With Gasket Diffuser Gasket Diffuser Impeller Shaft Seal Assembly Housing Gasket Seal Plate Page 19 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump Qty. 2 1 1 1 2 1 1 1 1 1 1 1 IS2600VSP Rev
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 20
    's Lube) 1 POWER END - SPX2600Z1VSPE Power End Assembly (Includes #7-14, motor and drive) 1 11. Troubleshooting 11.1. General Problems  Motor Will NOT Start: 1. Make sure the terminal board connections agree with the wiring diagram on the pump data plate label. 2. Be sure the pump is wired for
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 21
    causing seal damage, which will allow chlorinated water to seep into bearings wiping out the grease causing bearing to whine. All seal leaks should be replaced at once. Page 21 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 22
    Permanently Overload During Start Up Process Short Circuit Failure Multiple Errors at the Same Time, i.e. Undervoltage and Overload Error Communication Failure From controller 12. Warranty Page 22 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 23
    DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING AT 3,000 RPM (CLEAN FILTER) PUMP MODEL *Retain this Warranty Certificate in a safe and convenient location for your records Page 23 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev
  • Hayward Super Pump® VS | Super Pump® VS Manual - Page 24
    /installation or register online. Super Pump® VS Warranty Card Registration Please Print Clearly: Years Pool has been in service Installation Installation for: In Ground Spa Replacement is a registered trademark and Super Pump VS is a trademark of Hayward Industries, Inc. 2013 Hayward
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

IS2600VSP
Rev C
Hayward Pool Products
620 Division St, Elizabeth, NJ 07201
Phone: (908) 351-5400
www.haywardpool.com
VEUILLEZ VOUS REFERER AU SITE WEB
HAYWARDPOOL.CA
POUR LES INSTRUCTIONS EN FRANCAIS
Super Pump
®
VS
Owner’s Manual
Model
SP2600VSP
Super Pump Variable Speed Pump
The Hayward Super Pump VS is specifically engineered for the demanding requirements of today’s in-
ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning
equipment.
The totally enclosed, permanent magnet motor combined with its advanced hydraulic
design provides unparalleled energy savings. The Super Pump VS is a self-priming pump that
incorporates an improved seal and impeller design that will provide many years of efficient,
dependable, corrosion-free service.
The advanced design provides superior performance while
reducing maintenance requirements.
NOTE -
To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and
completely.
SAVE THIS INSTRUCTION MANUAL