Hayward Super Pump® VS Super Pump® VS Manual - Page 20

Troubleshooting

Page 20 highlights

Ref. Part No. Description Qty. No. 13 SPX1600F5 Motor Mounting Plate 1 14 SPX0125z44 Motor Cap Screws (Set of 4) 1 15 SPX1600Z4 Housing Cap Screw 4 16 SPX2600G1 Mounting Foot (Includes Screws) 1 17 SPX1600Z52 Mounting Foot Screws (Set of 2) 1 - SPXHKIT3 Quick Fix Kit (Includes #3, 7, 10, 11 & Jack's Lube) 1 POWER END - SPX2600Z1VSPE Power End Assembly (Includes #7-14, motor and drive) 1 11. Troubleshooting 11.1. General Problems  Motor Will NOT Start: 1. Make sure the terminal board connections agree with the wiring diagram on the pump data plate label. 2. Be sure the pump is wired for the available field supply voltage (230VAC). 3. Check for and correct any improper or loose wiring connections; open switches or relays; tripped circuit breakers, or blown fuses. 4. Manually check the rotation of the motor shaft for free movement and lack of obstruction. Correct if necessary.  Motor Shuts OFF: 1. Check for low voltage or power drop at the motor (frequently caused by undersized wiring). Contact a qualified professional to verify the electrical connections. 2. If the pump experiences an intermittent power failure short enough to remain power to the controller but not the pump, the pump will stop the motor. To resume function to the pump PRESS the RUN / STOP key or cycle power long enough to turn the controller off.  Motor Hums, But Does NOT Start: 1. Impeller jammed with debris. Have a qualified repair professional open the pump and remove the debris.  Pump Won't Prime: 1. Empty pump/strainer housing. Make sure the pump/strainer housing is filled with water and the cover gasket is clean. Ensure the gasket is properly seated in the cover gasket groove. Ensure the gasket sealing surface is lubricated with "Jack's 327" and that the strainer cover is locked firmly in position. Lubricant will help to create a tighter seal. 2. Loose connections on the suction side. Tighten the pipe/union connections. NOTE - Any self-priming pump will not prime if there are suction air leaks. Leaks will result in bubbles emanating from the return fittings on the pool wall. 3. Leaking O-ring or packing glands on valves. Tighten, repair, or replace the valves. 4. Strainer basket or skimmer basket loaded with debris. Remove the strainer housing cover or the skimmer cover. Clean the basket, and refill the strainer housing with water. Tighten the cover. Page 20 of 24 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Super Pump Variable Speed Pump IS2600VSP Rev C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 20 of 24
Super Pump Variable Speed Pump
IS2600VSP
Rev C
Ref.
No.
Part No.
Description
Qty.
13
SPX1600F5
Motor Mounting Plate
1
14
SPX0125z44
Motor Cap Screws (Set of 4)
1
15
SPX1600Z4
Housing Cap Screw
4
16
SPX2600G1
Mounting Foot (Includes Screws)
1
17
SPX1600Z52
Mounting Foot Screws (Set of 2)
1
-
SPXHKIT3
Quick Fix Kit (Includes #3,
7, 10, 11 & Jack’s Lube)
1
POWER END
-
SPX2600Z1VSPE
Power End Assembly (Includes #7-14, motor and drive)
1
11.
Troubleshooting
11.1.
General Problems
Motor Will NOT Start:
1.
Make sure the terminal board connections agree with the wiring diagram on the pump data plate label.
2.
Be sure the pump is wired for the available field supply voltage (230VAC).
3.
Check for and correct any improper or loose wiring connections; open switches or relays; tripped circuit
breakers, or blown fuses.
4.
Manually check the rotation of the motor shaft for free movement and lack of obstruction.
Correct if
necessary.
Motor Shuts OFF:
1.
Check for low voltage or power drop at the motor (frequently caused by undersized wiring).
Contact a
qualified professional to verify the electrical connections.
2.
If the pump experiences an intermittent power failure short enough to remain power to the controller but not
the pump, the pump will stop the motor.
To resume function to the pump PRESS the RUN / STOP key or cycle
power long enough to turn the controller off.
Motor Hums, But Does NOT Start:
1.
Impeller jammed with debris.
Have a qualified repair professional open the pump and remove the debris.
Pump Won't Prime:
1.
Empty pump/strainer housing.
Make sure the pump/strainer housing is filled with water and the cover
gasket is clean.
Ensure the gasket is properly seated in the cover gasket groove.
Ensure the gasket sealing
surface is lubricated with “Jack’s 327” and that the strainer cover is locked firmly in position.
Lubricant will
help to create a tighter seal.
2.
Loose connections on the suction side.
Tighten the pipe/union connections.
NOTE
- Any self-priming pump will not prime if there are suction air leaks.
Leaks will result in bubbles
emanating from the return fittings on the pool wall.
3.
Leaking O-ring or packing glands on valves.
Tighten, repair, or replace the valves.
4.
Strainer basket or skimmer basket loaded with debris.
Remove the strainer housing cover or the skimmer
cover.
Clean the basket, and refill the strainer housing with water.
Tighten the cover.