Hayward TriStar® VS Owners Manual - Page 13

TriStar Variable Speed Pump Control, USE ONLY HAYWARD GENUINE REPLACEMENT PARTS, VARIABLE SPEED

Page 13 highlights

TriStar Variable Speed Pump Control ____ Page 13 of 16 Timer deactivates the system. The system enters Off-Period Pump is stopped and system enters Stop Mode. System enters Stop Mode as before. *TIMER IS=OFF* *PUMP STOPPED* VARIABLE SPEED INTERFACE - BASIC OPERATION NOTES: 3) Timer Enabled (recommended): When the timer is enabled, the pump will be stopped when the control first receives power, until the Timer-ON time is reached, at which time it will prime and proceed through the steps defined in the Sequencer menu. The pump will stop when the system reaches the Timer-OFF time. The pump may be manually stopped by pressing the 5 and 6 buttons simultaneously for more than 5 seconds. Pressing any preset button after manually stopping the pump will cause the pump to prime and operate according to the preset chosen. Timer Disabled: When the timer is disabled, the pump will prime when the control first receives power, and will then default to P2 (Low Filter). It will continue to run according to P2 until power is disconnected from the control. After the pump has primed, the % Flow and Time Up/Dn buttons, as well as the 1-6 buttons, are active. Pressing any of the 1-6 buttons will cause the pump to run temporarily according to the set flow and time for the chosen preset. The % Flow and Time Up/Dn buttons may be used to temporarily modify the set flow and time for the chosen preset. After the chosen preset expires, the pump will default back to P2. The pump may be manually stopped by pressing the 5 and 6 buttons simultaneously for more than 5 seconds. After the pump is stopped, it may be restarted by pressing the 5 and 6 buttons simultaneously again for more than 5 seconds, at which point the pump will prime and then default to P2 (Low Filter). 4) RTC - Real Time Clock 5) Factory defaults are as follows. User/installer may note custom presets in the spaces provided. Mode Name PRIME 5 FEET OR LESS MORE THAN 5 FEET P1 Low P2 Low Filter P3 Medium Low P4 Medium High P5 High Filter Cleaner P6 Maximum Flow Factory Presets % Flow Time 65 6 min 85 8 min 50 30 min 50 30 min 50 30 min 50 30 min 50 30 min 50 30 min Custom Presets % Flow Time 6) If the sequencer is used, user/installer may note custom sequencer settings in the spaces provided. Sequence Step Timer On S1 S2 S3 S4 S5 S6 S7 S8 Timer Off Preset Used N/A N/A Duration N/A Time Start N/A WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

TriStar Variable Speed Pump Control
____
____________________________Page 13 of 16
WWW.HAYWARDPOOL.COM
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Timer deactivates the
system.
The system enters
Off-Period
Pump is stopped and
system enters Stop
Mode.
System enters Stop Mode as
before.
*TIMER IS=OFF*
*PUMP STOPPED*
VARIABLE SPEED INTERFACE - BASIC OPERATION NOTES:
3
)
Timer Enabled (recommended):
When the timer is enabled, the pump will be stopped when the control first receives power,
until the Timer-ON time is reached, at which time it will prime and proceed through the steps defined in the Sequencer menu.
The
pump will stop when the system reaches the Timer-OFF time.
The pump may be manually stopped by pressing the 5 and 6 buttons
simultaneously for more than 5 seconds.
Pressing any preset button after manually stopping the pump will cause the pump to prime
and operate according to the preset chosen.
Timer Disabled:
When the timer is disabled, the pump will prime when the control first receives power, and will then default to P2
(Low Filter).
It will continue to run according to P2 until power is disconnected from the control.
After the pump has primed, the %
Flow and Time Up/Dn buttons, as well as the 1-6 buttons, are active.
Pressing any of the 1-6 buttons will cause the pump to run
temporarily according to the set flow and time for the chosen preset.
The % Flow and Time Up/Dn buttons may be used to
temporarily modify the set flow and time for the chosen preset.
After the chosen preset expires, the pump will default back to P2.
The
pump may be manually stopped by pressing the 5 and 6 buttons simultaneously for more than 5 seconds.
After the pump is stopped, it
may be restarted by pressing the 5 and 6 buttons simultaneously again for more than 5 seconds, at which point the pump will prime
and then default to P2 (Low Filter).
4
)
RTC – Real Time Clock
5
)
Factory defaults are as follows.
User/installer may note custom presets in the spaces provided.
6
)
If the sequencer is used, user/installer may note custom sequencer settings in the spaces provided.
Sequence
Step
Preset
Used
Duration
Time Start
Timer On
N/A
N/A
S1
S2
S3
S4
S5
S6
S7
S8
Timer Off
N/A
N/A
Factory Presets
Custom Presets
Mode
Name
% Flow
Time
% Flow
Time
PRIME
5 FEET OR LESS
MORE THAN 5 FEET
65
85
6 min
8 min
P1
Low
50
30 min
P2
Low Filter
50
30 min
P3
Medium Low
50
30 min
P4
Medium High
50
30 min
P5
High Filter Cleaner
50
30 min
P6
Maximum Flow
50
30 min