Hayward W3SP3206VSP TriStar VS 950 - Owners Manual - Page 26

Diagnostic Menu, Stop/Resume

Page 26 highlights

6.9. Diagnostic Menu Screen 1. Diagnostic Menu Press > to enter 2. Press > to view next item 3. Display Revision 2.00 4. Drive Serial Number 3581200032 5. Comm Rev: 10.10 boardDranvd dRisepvla:y boa2r.d 00.65 Buttons Used < > Comments Use > to enter Diagnostic Menu and toggle between displays Displays firmware version of the display PCB. Displays motor drive serial number. Displays firmware revisions of the motor drive and drive interface PCB's. 6. SVRS Revision: 1:00 Status: Monitoring 7. Event log Press > to view Displays revision and status of integrated SVRS, if applicable. < > Use > to view event log Note: For troubleshooting purposes, the Event Log will record the last twenty error/trip conditions and/or status messages, as well as the amount of time that has elapsed since the condition occurred. See section 11.2 for more detail. 6.10. Stop/Resume Screen 1. Pump is stopped; press Stop/Resume 2. again to resume normal operation Note: When Stop/Resume is pressed at any time during normal operation, the above message will be displayed. The pump will stop within several seconds, and will remain stopped until Stop/Resume is pressed a second time, at which point the pump will resume normal operation. Page 26 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 2.70 THP VS Pump Family IS3206VSP3 Rev-B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 26 of 36
2.70 THP VS Pump Family
IS3206VSP3
Rev-B
6.9.
Diagnostic Menu
Buttons
Screen
Used
Comments
1.
< >
Use > to enter Diagnostic Menu
and toggle between displays
2.
3.
Displays firmware version of the display PCB.
4.
Displays motor drive serial number.
5.
Displays firmware revisions of the motor drive and drive
interface PCB’s.
6.
Displays revision and status of integrated SVRS,
if applicable.
7.
< >
Use >
to view event log
Note:
For troubleshooting purposes, the Event Log will record the last twenty error/trip conditions and/or status
messages, as well as the amount of time that has elapsed since the condition occurred. See section 11.2 for more
detail.
6.10.
Stop/Resume
Screen
1.
2.
Note:
When Stop/Resume is pressed at any time during normal operation, the above message will be displayed.
The pump will stop within several seconds, and will remain stopped until Stop/Resume is pressed a second time, at
which point the pump will resume normal operation.
Diagnostic Menu
Press > to enter
Display Revision
2.00
Drive Serial Number
3581200032
SVRS Revision: 1:00
Status: Monitoring
Event log
Press > to view
Pump is stopped;
press Stop/Resume
again to resume
normal operation
Comm Rev:
10.10
Drv Rev:
2.00.65
Press > to
view next item