Hayward W3SP3206VSP TriStar VS 950 - Owners Manual - Page 27

Maintenance

Page 27 highlights

6.11. Quick Clean Screen 1. SVRS inactive in Quick Clean mode 2. No bathers in water during Quick Clean 3. Bathers in water? + yes or - no Note: For SVRS pump models, the SVRS feature is disabled during Quick Clean mode. When Quick Clean is pressed, the above message is displayed to alert the user that SVRS is disabled, and that all bathers should exit the pool during Quick Clean. If bathers are in the water, pressing + will return the pump to normal operation. If bathers are not in the water, pressing - will allow the pump to run in Quick Clean mode, where it will run at the Max allowed speed set in the Configuration Menu for 60 minutes. When Quick Clean is selected for non-SVRS pump models, the pump will immediately proceed to Quick Clean mode. 4. SVRS Inactive Quick Clean running 5. SVRS Inactive 3450 rpm for 60 min; 6. SVRS Inactive press Resume to end Note: The above message will be displayed while Quick Clean is running. Quick Clean mode runs at the Max allowed speed and expires after 60 min, and it may be cancelled early by pressing the Stop/Resume button, at which time the pump would return to normal operation. Quick Clean can be extended up to 360 minutes with additional presses of the Quick clean button. For non-SVRS pump models, the SVRS Inactive message will not be shown. 6.12. Remote Stop Screen 1. Remote Stop is engaged Note: The above message will be displayed when an installed remote stop switch is activated. The pump will remain stopped until the remote stop switch is deactivated. See section 5.5 for more detail. 7. Maintenance  Clean strainer basket regularly. Do NOT strike basket. Inspect cover gasket regularly and replace as necessary.  Hayward pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.  Keep motor clean. Keep motor air vents free of obstructions to avoid damage. Do NOT use water to hose off motor.  Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit. See "Shaft Seal Change Instructions" in this manual. Page 27 of 36 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 2.70 THP VS Pump Family IS3206VSP3 Rev-B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 27 of 36
2.70 THP VS Pump Family
IS3206VSP3
Rev-B
6.11.
Quick Clean
Screen
1.
2.
3.
Note:
For SVRS pump models, the SVRS feature is disabled during Quick Clean mode.
When Quick Clean is pressed,
the above message is displayed to alert the user that SVRS is disabled, and that all bathers should exit the pool
during Quick Clean.
If bathers are in the water, pressing + will return the pump to normal operation.
If bathers are
not in the water, pressing – will allow the pump to run in Quick Clean mode, where it will run at the Max allowed
speed set in the Configuration Menu for 60 minutes.
When Quick Clean is selected for non-SVRS pump models, the
pump will immediately proceed to Quick Clean mode.
4.
5.
6.
Note:
The above message will be displayed while Quick Clean is running. Quick Clean mode runs at the Max allowed
speed and expires after 60 min, and it may be cancelled early by pressing the Stop/Resume button, at which time
the pump would return to normal operation.
Quick Clean can be extended up to 360 minutes with additional
presses of the Quick clean button. For non-SVRS pump models, the SVRS Inactive message will not be shown.
6.12.
Remote Stop
Screen
1.
Note:
The above message will be displayed when an installed remote stop switch is activated.
The pump will
remain stopped until the remote stop switch is deactivated. See section 5.5 for more detail.
7.
Maintenance
Clean strainer basket regularly.
Do NOT strike basket. Inspect cover gasket regularly and replace as necessary.
Hayward pumps have self-lubricating motor bearings and shaft seals.
No lubrication is necessary.
Keep motor clean.
Keep motor air vents free of obstructions to avoid damage. Do NOT use water to hose off motor.
Occasionally, shaft seals must be replaced, due to wear or damage.
Replace with genuine Hayward seal assembly
kit.
See “Shaft Seal Change Instructions” in this manual.
Remote Stop
is engaged
SVRS inactive in
Quick Clean mode
Bathers in water?
+ yes or - no
No bathers in water
during Quick Clean
SVRS Inactive
Quick Clean running
SVRS Inactive
press Resume to end
SVRS Inactive
3450 rpm for 60 min;