HP 8/40 Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June - Page 689
for more information., To initiate a system verification test on all switches in the fabric
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 689 highlights
systemVerification 2 Diagnostics Examples Each diagnostic test in this suit reports its own set of error messages when detecting a failure. Refer to the Diagnostics section of individual diagnostic test help pages. These messages are available only in the log file. Refer to the Fabric OS Message Reference for more information. To initiate a system verification test on all switches in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 SYSTEMVERIFICATION - label : BURNIN 2 - min_lb_mode : 2 1 - tbr_passes : 1 1 - prt_on : 1 1 - cntmem_on : 1 1 - cmi_on : 1 1 - retention_on : 1 1 - cam_on : 1 1 - flt_passes : 50 1 - sta_passes : 25 1 - plb_nframes : 100 1 - txd_nframes : 50 1 - xpt_nframes : 200 1 - bpt_nframes : 20 1 - slk_nmegs : 50 1 - bpt_all_nframes : 30 1 - slk_all_nmegs : 50 systemverification: Arming the burnin run on switch 0. systemverification: Starting burnin on Switch 0 systemverification: Monitoring progress of the burnin activity. systemverification: Outputting Status State Status Run Cmd TotCmds Script COMPLETED PASS 1 22 22 switchburnin.sh See Also burninErrShow, burninStatus, diagSetBurnin, diagSetCycle Fabric OS Command Reference 663 53-1000599-02