HP AE370A Brocade Web Tools Administrator's Guide v6.0.0 (53-1000606-01, April - Page 254

Displaying code information, Configuring FMS mode parameters

Page 254 highlights

19 Displaying code page information TABLE 15 FMS Mode Parameter Descriptions (Continued) Parameter Description Alternate Control Prohibited Determines whether alternate managers are allowed to modify port connectivity. Enabling this mode prohibits alternate manager control of port connectivity; otherwise, alternate managers can manage port connectivity. This parameter is set as enabled by the hardware after system installation, and can be reset by Web Tools. User Alert Mode Controls director console behavior for alerts. Enabling this mode prompts the director consoles to display a warning whenever you attempt an action that will change switch parameters. When you disable this mode, no warning is displayed. In this case, in which Web Tools is the director console, warning messages are displayed by Web Tools regardless of the setting of the parameter, since Web Tools always displays warning messages when you apply a change to a switch that changes parameters. This parameter is always read-only in Web Tools. Each time that the switch is powered on, the parameter is reset to disabled. Director Clock Alert Mode Host Control Prohibited Controls behavior for attempts to set the switch timestamp clock through the director console. When it is enabled, the director console (Web Tools, in this case) displays warning indications when the switch timestamp is changed by a user application. When it is disabled, you can activate a function to automatically set the timestamp clock. There is no indication for timestamp clock setting. This parameter is set as disabled by the hardware after system installation, and can be reset by Web Tools. Determines whether host programming allows modifying port connectivity. Enabling this mode prohibits host programming control of port connectivity; otherwise, host programming can manage port connectivity. This parameter is set as disabled by the hardware after system installation. and can be reset by Web Tools. Configuring FMS mode parameters 1. Click a FICON-enabled switch from the Fabric Tree. 2. Open the Switch Administration window as described on page 29. 3. Click the FICON CUP tab. The FICON CUP tabbed page displays, with the FICON Management Server subtabbed page in front (see Figure 107 on page 232). All attributes on this tab are read-only until FMS mode is enabled. 4. To enable or disable an FMS mode parameter, click the check box next to the parameter. A marked check box means that the parameter is enabled. You cannot configure the User Alert Mode parameter in Web Tools, as it is read-only. Displaying code page information The Code Page field identifies the language used to exchange information between the FICON director and Host Programming. It is a read-only field in Web Tools, as it is set by Host Programming only. When FMS mode is disabled, the code page is displayed as unavailable. 1. Click a FICON-enabled switch from the Fabric Tree. 2. Open the Switch Administration window as described on page 29. 234 Web Tools Administrator's Guide 53-1000606-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272

234
Web Tools Administrator’s Guide
53-1000606-01
Displaying code page information
19
Configuring FMS mode parameters
1.
Click a FICON-enabled switch from the
Fabric Tree
.
2.
Open the Switch Administration window as described on
page 29
.
3.
Click the
FICON CUP
tab.
The FICON CUP tabbed page displays, with the FICON Management Server subtabbed page in
front (see
Figure 107
on page 232). All attributes on this tab are read-only until FMS mode is
enabled.
4.
To enable or disable an FMS mode parameter, click the check box next to the parameter. A
marked check box means that the parameter is enabled. You cannot configure the User Alert
Mode parameter in Web Tools, as it is read-only.
Displaying code page information
The Code Page field identifies the language used to exchange information between the FICON
director and Host Programming. It is a read-only field in Web Tools, as it is set by Host Programming
only. When FMS mode is disabled, the code page is displayed as unavailable.
1.
Click a FICON-enabled switch from the
Fabric Tree
.
2.
Open the Switch Administration window as described on
page 29
.
Alternate Control
Prohibited
Determines whether alternate managers are allowed to modify port connectivity.
Enabling this mode prohibits alternate manager control of port connectivity; otherwise,
alternate managers can manage port connectivity.
This parameter is set as enabled by the hardware after system installation, and can be reset by
Web Tools.
User Alert Mode
Controls director console behavior for alerts.
Enabling this mode prompts the director consoles to display a warning whenever you attempt
an action that will change switch parameters. When you disable this mode, no warning is
displayed. In this case, in which Web Tools is the director console, warning messages are
displayed by Web Tools regardless of the setting of the parameter, since Web Tools always
displays warning messages when you apply a change to a switch that changes parameters.
This parameter is always read-only in Web Tools. Each time that the switch is powered on, the
parameter is reset to disabled.
Director Clock
Alert Mode
Controls behavior for attempts to set the switch timestamp clock through the director console.
When it is enabled, the director console (Web Tools, in this case) displays warning indications
when the switch timestamp is changed by a user application. When it is disabled, you can
activate a function to automatically set the timestamp clock. There is no indication for
timestamp clock setting.
This parameter is set as disabled by the hardware after system installation, and can be reset
by Web Tools.
Host Control
Prohibited
Determines whether host programming allows modifying port connectivity.
Enabling this mode prohibits host programming control of port connectivity; otherwise, host
programming can manage port connectivity.
This parameter is set as disabled by the hardware after system installation. and can be reset
by Web Tools.
TABLE 15
FMS Mode Parameter Descriptions
(Continued)
Parameter
Description