HP AM866A Brocade Fabric OS Command Reference v6.3.0 (53-1001337-01, July 2009 - Page 160
TABLE 12, System Settings
UPC - 884420064602
View all HP AM866A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 160 highlights
2 configureChassis Custom Attributes Table 11 lists custom attributes that may be modified. TABLE 11 Configurable custom attributes Application Attribute Custom Config Index (0 to ignore): Type Number Default 0 Range 0-10000 config Index OEM custom configuration. This attribute is for internal use only. System Settings The following system-related parameters are configurable on a Virtual Fabric-aware switch. TABLE 12 System settings Field Type Default Range system.blade.bladeFaultOn Number 0x0 HwErrMsk 0x0 to 0xffff system.blade.bladeFaultOnHwErrMsk If this field is set to a value other than 0, then any nonfatal HW ASIC data parity error causes the problem blade to be powered off. Examples To enable signature validation for downloading firmware: switch:admin> configurechassis Not all options will be available on an enabled switch. To disable the switch, use the "switchDisable" command. Configure... cfgload attributes (yes, y, no, n): [no] y Enforce secure config Upload/Download (yes, y, no, n): [no] Enforce signature validation for firmware (yes, y, no, n): [no]yes Custom attributes (yes, y, no, n): [no] System (yes, y, no, n): [no] See Also configDefault, configShow, chassisEnable, chassisDisable, configure, ipAddrSet, portCfgLongDistance, switchDisable, switchEnable, upTime 130 Fabric OS Command Reference 53-1001337-01