HP AM866A Brocade Fabric OS Command Reference v6.3.0 (53-1001337-01, July 2009 - Page 461
iscsiPathTest, Synopsis, nframes, Description, Notes, Operands, Examples, See Also, iscsiChipTest
UPC - 884420064602
View all HP AM866A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 461 highlights
iscsiPathTest 2 iscsiPathTest Synopsis Performs functional test of components in iSCSI complex. iscsipathtest --slot slotnumber -unit number -path mode -nframes count Description Use this command to verify the functions of the network processor and the iSCSI complex. Multiple frames or data packets are transmitted from the Network processor to designated loopback points and sent back. The command checks statistics, frame counts, data path, and hardware connections in the iSCSI complex. You can set the data path mode with the -path option. Notes This command is supported only on the Brocade FR4-16IP blade. On all other platforms, this command displays the message: "Command not applicable to this platform. SKIPPED!" The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command Availability" for details. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which to run the diagnostics. The default is set to 0 and designed to operate on fixed-port-count products. -unit number Specifies the GbE port to test. By default all the GbE ports in the specified slot are tested. . Specify an integer between 0 and 7 or 8 to specify all ports. -path mode Selects the loopback point for the test. By default, iscsiPathTest uses PHY and Central ASIC loopback. Valid values are: 1 Data packets from network processor to GbE RJ-45 loopback. 2 Data packets from network processor to GbE PHY loopback. 3 Data packets from network processor to GbE GMAC loopback. 4 FC frames from network processor to Central ASIC FC Serdes loopback. 5 FC frames from network processor to serial loopback at iFlipper FC serdes. 6 FC frames from network processor to parallel loopback at iFlipper FC serdes. 9 -nframes count Data packets from network processor to loopback at network processor 8-bit FIFO. Specifies the number of frames to send. The test progresses until the specified number of frames has been transmitted on each port. The default value is 100. Examples To run iscsipathtest: switch:admin> iscsipathtest --slot 2 -path 2 -nframes 10 Running iscsipathtest Test Complete: iscsipathtest Pass 10 of 10 Duration 0 hr, 3 min & 1 sec (0:3:0:630). passed. See Also iscsiChipTest Fabric OS Command Reference 431 53-1001337-01