HP Brocade 8/12c HP Fabric OS 6.2.2f Release Notes (5697-1756, February 2012) - Page 38
continued, FCIP tunnels on the HP StorageWorks 400 MP Router or the MP Router
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Table 8 Fabric OS 6.2.1 closed defects (continued) Closed defect summary HA failover on HP StorageWorks DC SAN director times out, causing a switch reboot. Solution Fixed in Fabric OS 6.2.1 Workaround prior to update: Manually block/unblock an E_Port to rebuild the fabric. Daemons may panic during FID (logical switch) deletion and creation if there is no significant time delay between the deletion and creation. The switch becomes unresponsive and the daemon panics. Fixed in Fabric OS 6.2.1 In a FICON environment, a switch may panic when blocking/unblocking Fixed in Fabric OS 6.2.1 an E_Port due to incorrect RNID data count. Concurrent reboot of HP StorageWorks DC SAN directors at both ends of Fixed in Fabric OS 6.2.1 DWDM link causes the link to fail to come up, because the link is unable to sync before the port is enabled at the correct speed. Devices attached to a switch in Access Gateway mode are reported by DCFM/weblinker as physical rather than virtual devices. Fixed in Fabric OS 6.2.1 A switch reboot/hafailover with kernel assert in the FCPH module occurs Fixed in Fabric OS 6.2.1 when the received frame size is too big. In an FCR environment (with a router or switch configured for FCR), a switch Fixed in Fabric OS 6.2.1 runs out of memory when it is connected with the Mi10k. The Mi10k sends continuous RRQ frames because the Fabric OS-based switch did not handle RRQ frames with either accept or reject. Several problems occurred that were related to the configdownload commands. Some of these problems caused a core dump. Fixed in Fabric OS 6.2.1 A switch panic/hafailover occurs due to a weblinker.cfg panic seen during overnight slot command script test when modify/distribute ACL database, and during RNID response processing. Fixed in Fabric OS 6.2.1 A blade fault occurred in HP StorageWorks 4/256 SAN director on an 8-Gb 48-port blade in either slot 1 or slot 10 when the director was fully loaded with 8-Gb 48-port blades. Fixed in Fabric OS 6.2.1 Starting with Fabric OS 6.1.2, supportsave was updated to collect more Fixed in Fabric OS 6.2.1 data. A Parity error may be logged as data is read from disabled ports on switches that were updated from a lower code level but never cold booted. Frame Redirect zones cannot be created when defzone is set to allaccess. Fixed in Fabric OS 6.2.1 Workaround prior to update: Set defzone to noaccess. Memory leak during security script testing. Fixed in Fabric OS 6.2.1 In 8-Gb routed fabric, PLOGI in acceleration path did not program cam Fixed in Fabric OS 6.2.1 entry properly, leading to backbone hosts not being able to see edge fabric target. FCIP tunnels on the HP StorageWorks 400 MP Router or the MP Router blade do not come up due to a timing issue caused when using optical-to-copper converters in the path. Fixed in Fabric OS 6.2.1 In a cascaded Access Gateway configuration of three switches with both Fixed in Fabric OS 6.2.1 AGs in port group mode, when the QoS license is removed from the fabric switch and switchdisable/enable is performed, traffic continues for medium priority flows, but stops flowing for high and low priorities until the QoS license is reinstalled. When a trunk master port is disabled, Fabric Watch incorrectly sets the new trunk master's health to offline and the remote side to faulty, even though the port is online. This is a Web Tools display problem with no functionality impact. Fixed in Fabric OS 6.2.1 38