HP Brocade 8/12c HP Fabric OS 6.2.2f Release Notes (5697-1756, February 2012) - Page 50

Effective date, Table 17 Fabric OS 6.2.2e closed defects

Page 50 highlights

Table 17 Fabric OS 6.2.2e closed defects (continued) Closed defect summary Solution 0. No data is being sent on the loop for an extended period of time. SNMP traps and related RASLOGs may not be generated as expected. For example, SNMP-1008 messages and traps stop while a port is bouncing every 20 minutes. Fixed in Fabric OS 6.2.2f. A kernel panic may occur while accessing the compact Fixed in Fabric OS 6.2.2f. flash and may result in a switch reboot. IPv6 named Certificate Signing Request (CSR) files may contain characters such as "*.*" which are not accepted by some windows-based servers, causing file transfers (FTP) to fail. Fixed in Fabric OS 6.2.2f. Upon upgrading a fabric switch to Fabric OS 6.4.1 Fixed in Fabric OS 6.2.2f. or later, F_Port trunking used to connect any Access Workaround prior to update: Gateways (running Fabric OS 6.1.x or 6.2.x) are not allowed if the fabric switch does not have a Server Install an SAO license on the switch running Fabric OS 6.2.x Application Optimization (SAO) license installed. This (or earlier) in AG mode. eventually results in connectivity loss between the Access Gateway and the fabric switch if attached with F_Port trunks. The seccertutil genkey does not work with Fixed in Fabric OS 6.2.2f. autogenerated IPv6 addresses, and reports Configure a Valid IPv4 or IPv6 address when there already is a valid IPv6 address. An HA Failover on the HP StorageWorks 4/256 SAN Fixed in Fabric OS 6.2.2f. Director with any HP StorageWorks DC SAN Director FC Blade (16-port, 32-port or 48-port) installed may result in a rare race condition, and a reset of the port blades may cause temporary traffic disruption. There is no support for SFTP in Fabric OS. Fixed in Fabric OS 6.2.2f. A switch running Fabric OS 6.2.2e or earlier versions Fixed in Fabric OS 6.2.2f. of 6.2.x connected to a 16 Gb port on a switch running Fabric OS 7.0.x or later will segment the E_Port links, when QOS is enabled on ports at both ends of the link. Enabling track changes in native mode keeps the Fixed in Fabric OS 6.2.2f. feature active when Access Gateway (AG) mode is enabled but the CLI no longer functions in AG mode. Switch Ethernet ports may send frames with invalid Fixed in Fabric OS 6.2.2f. Ethernet MAC addresses on the HP 8/80 48-ports SAN Switch or the HP 1606 SAN Extension Switch. There is no functional impact because of successful Workaround prior to update: Use 100 half duplex instead of full duplex mode. TCP/IP frame retransmits. However, if security software monitors each frame, it will trigger alarms upon detection of an invalid MAC address. Effective date February 2012 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

Table 17 Fabric OS 6.2.2e closed defects
(continued)
Solution
Closed defect summary
0. No data is being sent on the loop for an extended
period of time.
Fixed in Fabric OS 6.2.2f.
SNMP traps and related RASLOGs may not be
generated as expected. For example, SNMP-1008
messages and traps stop while a port is bouncing
every 20 minutes.
Fixed in Fabric OS 6.2.2f.
A kernel panic may occur while accessing the compact
flash and may result in a switch reboot.
Fixed in Fabric OS 6.2.2f.
IPv6 named Certificate Signing Request (CSR) files
may contain characters such as “*.*” which are not
accepted by some windows-based servers, causing
file transfers (FTP) to fail.
Fixed in Fabric OS 6.2.2f.
Upon upgrading a fabric switch to Fabric OS 6.4.1
or later, F_Port trunking used to connect any Access
Workaround prior to update
:
Gateways (running Fabric OS 6.1.x or 6.2.x) are not
Install an SAO license on the switch running Fabric OS 6.2.x
(or earlier) in AG mode.
allowed if the fabric switch does not have a Server
Application Optimization (SAO) license installed. This
eventually results in connectivity loss between the
Access Gateway and the fabric switch if attached with
F_Port trunks.
Fixed in Fabric OS 6.2.2f.
The
seccertutil genkey
does not work with
autogenerated IPv6 addresses, and reports
Configure a Valid IPv4 or IPv6 address
when there already is a valid IPv6 address.
Fixed in Fabric OS 6.2.2f.
An HA Failover on the HP StorageWorks 4/256 SAN
Director with any HP StorageWorks DC SAN Director
FC Blade (16-port, 32-port or 48-port) installed may
result in a rare race condition, and a reset of the port
blades may cause temporary traffic disruption.
Fixed in Fabric OS 6.2.2f.
There is no support for SFTP in Fabric OS.
Fixed in Fabric OS 6.2.2f.
A switch running Fabric OS 6.2.2e or earlier versions
of 6.2.x connected to a 16 Gb port on a switch
running Fabric OS 7.0.x or later will segment the
E_Port links, when QOS is enabled on ports at both
ends of the link.
Fixed in Fabric OS 6.2.2f.
Enabling track changes in native mode keeps the
feature active when Access Gateway (AG) mode is
enabled but the CLI no longer functions in AG mode.
Fixed in Fabric OS 6.2.2f.
Switch Ethernet ports may send frames with invalid
Ethernet MAC addresses on the HP 8/80 48-ports
Workaround prior to update
:
SAN Switch or the HP 1606 SAN Extension Switch.
Use 100 half duplex instead of full duplex mode.
There is no functional impact because of successful
TCP/IP frame retransmits. However, if security software
monitors each frame, it will trigger alarms upon
detection of an invalid MAC address.
Effective date
February 2012