HP Brocade 8/12c HP Fabric OS 6.2.2f Release Notes (5697-1756, February 2012) - Page 47

Fabric OS 6.2.2d fixes, Table 14 Fabric OS 6.2.2c closed defects

Page 47 highlights

Table 14 Fabric OS 6.2.2c closed defects (continued) Closed defect summary Solution /fabos/libexec/webdconfigure as root to set "HTTP Enable" to yes. Or schedule a window, disable switch, and configdownload a file with http.enable:1 [end] when switch is at FOS 6.1.x to correct the configuration. If the switch is already stuck in a reboot loop, login as root via serial console, copy and paste the following command string into console as one line before the next reboot: sed 's/http.enabled:1/http.enabled:1/g' tmp; cp tmp /etc/fabos/fabos.0.conf;cp tmp /mnt/etc/fabos/fabos.0.conf;rm tmp After hot code load, switch in access gateway mode Fixed in Fabric OS 6.2.2c. panics and reboots, and usually a [PORT-1003] is entered in raslog. VE tunnel bounce, VEx/Ex port bounce observed after Fixed in Fabric OS 6.2.2c. hareboot on 8 Gb switch configured for FCR under heavy load condition. This impacts HP StorageWorks 400 Multiprotocol router, multiprotocol router blade, or any 8 Gb switch configured with VEx/Ex/VE ports. All 64 bit port status counters not available in SNMP, Fabric OS 6.2.2c now exposes these counters through SNMP even though they are available in the CLI using the portStats64Show command. Running supportsaves -k multiple times on FOS 6.2.x causes raslogd to crash and restart. This can lead to hafailover on directors and reboot on switches. Fixed in Fabric OS 6.2.2c. On B-series 4 Gb switches, multiple critical level With Fabric OS v6.2.2c, this specific occurrence of CDR-1003 CDR-1003 raslog entries seen during is updated to log as a warning rather than critical. It can be supportsave after non-disruptive upgrade from FOS safely ignored unless it becomes persistent, or does not happen 6.1.x to 6.2.x. during supportsave. WebTools nameserver is not reflecting the alias and Fixed in Fabric OS 6.2.2c. zones created in DCFM. Alias and zone to which the Workaround prior to update: device belongs is not displayed in the "member of zone" and "member of alias" column. Use WebTools to create a zone/alias rather than DCFM. Fabric OS 6.2.2d fixes Table 15 (page 47) lists defects closed in the Fabric OS 6.2.2d firmware release. Table 15 Fabric OS 6.2.2d closed defects Closed defect summary Solution During a reboot, the host might not come up when Fixed in Fabric OS 6.2.2d. connected to an HP StorageWorks 4/8 SAN Switch, HP StorageWorks 4/16 SAN Switch, or Brocade 4 Gb SAN Switch for HP c-Class BladeSystem. The host is unable to log in because the switch comes online as a G_Port rather than an F_Port. Weblinker processes terminate and then restart when Fixed in Fabric OS 6.2.2d. the DCFM management application queries Top Talker information from the switch. For all 8 Gb switches, the host is unable to discover Fixed in Fabric OS 6.2.2d. its targets after an HA failover or a code upgrade on the router port. This is because the domain table routing entry is accidentally cleared on an EX_Port. Fabric OS 6.2.2d fixes 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

Table 14 Fabric OS 6.2.2c closed defects
(continued)
Solution
Closed defect summary
/fabos/libexec/webdconfigure
as
root
to set "HTTP
Enable" to
yes
. Or schedule a window, disable switch, and
configdownload
a file with
http.enable:1 [end]
when
switch is at FOS 6.1.x to correct the configuration.
If the switch is already stuck in a reboot loop, login as
root
via serial console, copy and paste the following command string
into console as one line before the next reboot:
sed 's/http.enabled:1/http.enabled:1/g'
</etc/fabos/fabos.0.conf> tmp;
cp tmp /etc/fabos/fabos.0.conf;cp tmp
/mnt/etc/fabos/fabos.0.conf;rm tmp
Fixed in Fabric OS 6.2.2c.
After hot code load, switch in access gateway mode
panics and reboots, and usually a
[PORT-1003]
is
entered in
raslog
.
Fixed in Fabric OS 6.2.2c.
VE tunnel bounce, VEx/Ex port bounce observed after
hareboot
on 8 Gb switch configured for FCR under
heavy load condition. This impacts HP StorageWorks
400 Multiprotocol router, multiprotocol router blade,
or any 8 Gb switch configured with VEx/Ex/VE ports.
Fabric OS 6.2.2c now exposes these counters through SNMP
All 64 bit port status counters not available in SNMP,
even though they are available in the CLI using the
portStats64Show
command.
Fixed in Fabric OS 6.2.2c.
Running
supportsaves -k
multiple times on FOS
6.2.x causes
raslogd
to crash and restart. This can
lead to
hafailover
on directors and reboot on
switches.
With Fabric OS v6.2.2c, this specific occurrence of CDR-1003
is updated to log as a warning rather than critical. It can be
On B-series 4 Gb switches, multiple critical level
CDR-1003
raslog
entries seen during
safely ignored unless it becomes persistent, or does not happen
during
supportsave
.
supportsave
after non-disruptive upgrade from FOS
6.1.x to 6.2.x.
Fixed in Fabric OS 6.2.2c.
Workaround prior to update:
WebTools
nameserver
is not reflecting the alias and
zones created in DCFM. Alias and zone to which the
Use WebTools to create a zone/alias rather than DCFM.
device belongs is not displayed in the "member of
zone" and "member of alias" column.
Fabric OS 6.2.2d fixes
Table 15 (page 47)
lists defects closed in the Fabric OS 6.2.2d firmware release.
Table 15 Fabric OS 6.2.2d closed defects
Solution
Closed defect summary
Fixed in Fabric OS 6.2.2d.
During a reboot, the host might not come up when
connected to an HP StorageWorks 4/8 SAN Switch,
HP StorageWorks 4/16 SAN Switch, or Brocade 4
Gb SAN Switch for HP c-Class BladeSystem. The host
is unable to log in because the switch comes online
as a G_Port rather than an F_Port.
Fixed in Fabric OS 6.2.2d.
Weblinker processes terminate and then restart when
the DCFM management application queries Top Talker
information from the switch.
Fixed in Fabric OS 6.2.2d.
For all 8 Gb switches, the host is unable to discover
its targets after an HA failover or a code upgrade on
the router port. This is because the domain table
routing entry is accidentally cleared on an EX_Port.
Fabric OS 6.2.2d fixes
47